Replacing the Fuse
1. Disconnect the product from power.
2. Using a flat head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove blown fuse and replace with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The Maverick MK3 Profile CX will work with a DMX controller using a 3- or 5-pin DMX serial connection. A DMX Primer is
available from www.chauvetprofessional.com.
DMX Connection
The Maverick MK3 Profile CX uses a 3- or 5-pin DMX data connection for its DMX personalities: 38Ch and 54Ch. See
the User Manual for information about connecting and configuring the product for DMX operation.
Signal Connection
The Maverick MK3 Profile CX can link to controller software using an Ethernet connection. If using other Art-Net™ or
sACN -compatible products with the Maverick MK3 Profile CX, you can control each individually on a single network. See
the User Manual for information about how to connect and configure the product for these signals.
Art-Net
Connection
™
Art-Net™ is an Ethernet protocol that uses TCP/IP which transfers a large amount of DMX512 data using an Neutrik®
etherCON® RJ45 connection over a large network. An Art-Net™ protocol document is available from
www.chauvetprofessional.com. Chauvet Professional recommends using unicast Art-Net™ for best results.
Art-Net™ designed by and copyright Artistic Licence Holdings Ltd.
sACN Connection
Also known as ANSI E1.31, Streaming-ACN is an Ethernet protocol that uses the layering and formatting of Architecture
for Control Networks to transport DMX512 data over IP or any other ACN compatible network.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller's User Manual or with the manufacturer as not all DMX controllers
have this capability. The Maverick MK3 Profile CX supports RDM protocol that allows feedback to make changes to
menu map options. Download the User Manual from
Mounting
Before mounting this product, read the
mounting clamps are capable of supporting the weight of the product. For our Chauvet line of mounting clamps, go to
http://trusst.com/productcategory/truss-clamps/.
Mounting Diagram
Overhead Mounting
Maverick MK3 Profile CX QRG Rev. 1
QUICK REFERENCE GUIDE
www.chauvetprofessional.com
Safety
Notes. Use at least two mounting points per product. Make sure the
Mounting Clamp
Safety Cable
for more details.
Floor Mounting
EN