BX+ V2
DeltaSol
®
3. System description stratified layer module basic scheme with additional pool
(Scheme number 003 / 013)
In this scheme, a pool is integrated into the solar circuit via
a heat exchanger. In this case, the stratified store has first
priority. Only when loading is not possible any more, will
the controller switch to pool loading.
KIOTO Clear Energy AG
A - 9300 St. Veit a.d. Glan
DeltaSol
BX+ V2
®
S1
S2
RPD
1
2
3
4
S9
S10
PWMA
V40
V40
VFD
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
S1
R1
Note: In scheme 013, connect the pump R1 to PWM A, R3 to PWM C and R2 to PWM B additionally.
Vor Öffnen Gerät spannungslos schalten!
Isolate mains before removing cover!
Masse-Sammelklemme benutzen
Use ground common terminal block
Neutralleiter-Sammelklemme benutzen!
N
Use neutral conductor common terminal block
Schutzleiter-Sammelklemme benutzen
Use PE Common terminal block
Temp. Sensor
S3
S4
S5
S6
S7
S8
5
6
7
8 9 10 11 12 13 14 15 16
PWMB
PWMC
PWMD
CS10 VBus
0-10V
0-10V
0-10V
0-10V
R4
S3
S5
(V1)
Store 1
R3
Relay 2 (R2) can be used as a control signal, e. g. for switch-
ing an external contactor that controls the additional pool
loading pump.
R1-R4
1 (1) A (100 ... 240) V~
R5
4 (1) A 240 V~
4 (1) A 24V
IP20
S7
Swimming pool
S2
R2
T4A
100 ... 240 V~
50-60 Hz
L' L
N
S4
13
|