C: CONNECT TO DISpLAY UNIT D279
The detector can be
connected to Display
unit D279 with software
version 1.06 or newer.
C1. START pROGRAM 29. The laser shall be placed
at the Stationary (S) machine and the detector at
the Movable (M).
Alt. 1
S
M
C2. fACE THE SIDE Of THE SHEAvE on which
the BTA shall be attached to and choose with
between the above shown settings; movable (M)
machine to the right or to the left of the stationary
machine.
Confirm with
C3. MEASURE AND ENTER THE DISTANCE
between the feet pair F1 and F2 on the movable
machine.
Confirm distance with
[ Back
]
Alt. 2
M
S
C4. ENTER THE SHEAvE fACE wIDTH
If equal widths on both the sheaves, accept [ _ ]
with
for both S and M sheave.
If different widths, enter each width S and M.
Confirm each figure with
[ Back
]
C5. MEASUREMENT vALUES ARE DISpLAYED
All values in live mode. Adjust within acceptable
tolerance. Save or Print out the measurement result
if wanted. [Back
Example: The machine leans
backwards 0.09°, and with the feet
distance entered (in step C3) this
will give a height difference of 0.7
between the feet pair F1 and F2.
Vertical
Example: The offset
+1.5 means that the
M sheave is before
the S sheave.
Offset
]
Horizontal