Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
6159936270
Issue no: 08
Series: G
© COPyRIGHT 2014, DESOUTTER HP2
7SJ UK
All rights reserved. Any unauthorized use or copying of
the contents or part thereof is prohibited. This applies
in particular to trademarks, model denominations,
part numbers and drawings. Use only authorized
parts. Any damage or malfunction caused by the use
of unauthorised parts is not covered by Warranty or
Product Liability.

STATEMENT OF USE

Product is designed for installing and removing
threaded fasteners in wood, metal and plastic. No other
use permitted. For professional use only.
The suspension bail had been designed for vertical
use of the screwdriver. For any other use, it is
recommended to add the accessory P / N 6153979205
(retainer).
DATA
● Class of construction: III
● Rated input: 53W
● Rated current: 2,2A
● Rated voltage: 40VDC
● Weight: 0,64Kg - 0,84Kg
● Noise level: < 70 dB(A). (EN 60 745)
● Vibration level: < 2.5 m/s². (EN 60 745)
Declaration of noise and vibration emission
All values are current as of the date of this publication.
For the latest information please visit cp.com.
These declared values were obtained by laboratory
type testing in accordance with the stated standards
and are suitable for comparison with the declared
values of other tools tested in accordance with the
same standards. These declared values are not
adequate for use in risk assessments and values
measured in individual work places may be higher. The
actual exposure values and risk of harm experienced
by an individual user are unique and depend upon the
way the user works, the workpiece and the workstation
design, as well upon the exposure time and the
physical condition of the user.
We, Chicago Pneumatic, cannot be held liable for the
consequences of using the declared values, instead of
values reflecting the actual exposure, in an individual
risk assessment in a work place situation over which
we have no control.
This tool may cause hand-arm vibration syndrome if
its use is not adequately managed. An EU guide to
managing hand-arm vibration can be found at http://
www.humanvibration.com/EU/VIBGUIDE.htm
We recommend a programme of health surveillance
to detect early symptoms which may relate to noise or
vibration exposure, so that management procedures
can be modified to help prevent future impairment.
REQUIREMENTS
These tools can only be used with an ESP7 controller.
ACCESSORIES
A wide range of accessories are available and suitable
items should be selected from the relevant Desoutter
Catalogue.
ADJUSTMENTS
Perform regular torque accuracy checks.
To set the Hall Effect :
● Hold Case Front Grip (PtNo 463683) firmly and
unscrew Clutch Case (PtNo 443843).
● Hold Rear Case halves firmly and remove front grip
by carefully pulling it off. (A slight twisting action
may help loosen it).
● Loosen nylon screws securing Hall Effect Assembly
(PtNo 471953).
● With a PZ1 Screwdriver, turn the Adjuster Ring
to align the arrows on the Hall Effect Assembly &
Signal Case Assembly (Nº 461353).
When checking the tool functionality, always
replace front grip along with clutch and
clutch case. Damage to the tool may occur if
grip not replaced.
● Check tool functions correctly.
● If tool does not function, move Hall Effect Assembly
+ or - in 0.5mm steps. (1mm per full turn of the
adjuster ring).
● After adjustment, fit and tighten two nylon screws,
and apply a small amount of Varn-istop (PtNo
440783).
● Replace front grip along with clutch and clutch case.
Tighten clutch case (Torque 7 Nm).
● Test tool for correct function and check / set torque.
OPERATING INSTRUCTIONS
IMPORTANT: This tool is fitted with
temperature sensing. If the temperature
inside the tool motor area exceeds a pre set
temperature, the ESP7 Controller will disable
the tool and display, ERROR 013.
Should this Error occur, the reason for this must be
established (E.g. Tool being used out side of cycle
times stated, at too higher torque, in too high an
ambient temperature, or tool has become defective
etc.).
Note: The Error 013 message will clear and the tool will
be re useable after the internal temperature has cooled
sufficiently. Alternatively, use another tool.
With the correct accessory fitted, connect the tool to the
ESP 7 controller.
Ensure all Forward and Reverse times / Speeds,
Current and special function parameters are
programmed correctly in the "SETUP – MODE" and
"PROGRAM GROUP " parameters to be used for the
12 / 44
WARNING
WARNING
10/2014

Publicidad

Tabla de contenido
loading

Tabla de contenido