Nordson iControl Manual De Hardware página 115

Ocultar thumbs Ver también para iControl:
Tabla de contenido

Publicidad

In/Out Positioner Panel
120 Vac
PN 1055889 or
PN 1055883 (retrofit) or
PN 1070103 (reciprocator)
Control Panel
Power Supply
Ethernet
FieldBus Controller
Reciprocator Speed
Controller
3 Phase In
Powder Booth
Positioner Control Panel
PN 1055889 (In/Out)
PN 1058883 (In/Out Retrofit)
PN 1070103 (In/Out+Reciprocator)
Control Panel
120 Vac
Power Supply
FieldBus Controller
Reciprocator Speed
3 Phase In
Controller
Figure 7-1
iControl System Diagram
E 2011 Nordson Corporation
AC J−Box (J−5)
AC In
Network Interface Panel
PN 1057333
AC Adapter
Terminals for
Encoder Input
Zone Input
Part ID Inputs
Ethernet Switch
AC Out
Booth Control Panel
Ethernet
Ethernet
Power
CAN
Ethernet
Ethernet Field Connection
NOTE: Your system may not have
all
the options shown here.
AC Out
iControl Enclosure
AC In
iControl PC
CAN
PC104
CAN
RIBBON
iFlow Modules
Gun Control Cards
16
Gun Cables
CAN IN
CAN
AC In
25-Conductor Input Cable
Ethernet
25-Conductor Input Cable
Run in one
common conduit
Remote Part ID / Photoeye / Scanner Stand
120 Vac
Power Supply
24 Vdc
Terminals:
Encoder Inputs
Zone Inputs
Part ID Inputs
In/Out Positioner
Scanner J-Box
PN 1055890
Ether
I/O
net
Ethernet
PC104
PCI
Analog
Scanner
Controller
Isolated
Input Interface
FieldBus
Coupler
AC Adapter
CAN OUT
To
Slave
CAN
Console
CAN AUX
Power Supply
Ethernet
100 Meter Length Limit
7-3
Wiring and Pneumatic Diagrams
NOTE:
AC Adapter, Ethernet
Switch, and dashed line
wiring are Booth #2
Optional Components.
30 Watt Photoeye
J-Box
PN 1035897
Run in one
To Booth #2
common conduit
(Optional)
Pieza 7169367A

Publicidad

Tabla de contenido
loading

Tabla de contenido