Descargar Imprimir esta página

OBERON 1052-CP Guia De Instalacion página 2

Publicidad

Installation Guide /
Guía de instalación
for Oberon Model 1052-CP & 1052-DOME
para Modelo Oberon 1052-CP & 1052-DOME
1
Find a flat work surface to assemble the ceiling enclosure, access point, and
antenna(s) prior to mounting in ceiling.
Place the ceiling enclosure backbox on the work surface. Determine which
knockout is to be used to bring in the data cable and remove the knockout.
Install the conduit fitting from the inside of the enclosure. Insert the conduit
fitting through the hole with the nut installed from the outside of the enclo-
sure.
NOTE: A surface mount box (or biscuit jack) and equipment cord can be
conveniently mounted inside the Model 1052. (Non-plenum rated cables can
be used inside a plenum rated enclosure). Use an adhesive backed surface
mount box. Consider bend radius of horizontal cable and equipment cord
when attaching the surface mount box.
Encuentre una superficie de trabajo plana para ensamblar el recinto del
techo, el punto de acceso y las antenas antes de montarlo en el techo.
Coloque la caja de conexiones del techo en la superficie de trabajo. Deter-
mine qué knockout se usará para introducir el cable de datos y elimine el
knockout. Instale la conexión del conducto desde el interior del gabinete.
Inserte la conexión del conducto a través del orificio con la tuerca instalada
desde el exterior del gabinete.
NOTA: Una caja de montaje en superficie (o un conector para galletas) y un
cable de equipo se pueden montar convenientemente dentro del Modelo
1052 (Los cables sin capacidad de plenum se pueden usar dentro de un
recinto con capacidad de plenum). Use una caja de montaje en superficie
con adhesivo. Considere el radio de curvatura del cable horizontal y del
cable del equipo cuando conecte la caja de montaje en superficie.
2
Install the provided T-bar mount into the enclosure.
Instale la montura T-bar provista en el gabinete.
"Oberon" and all other marks where denoted are trademarks of Oberon Inc.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1999-2020 Oberon Incorporated. Todos los derechos reserve.
3
Use the manufacturer's T-bar mount clip to attach the AP to the T-bar
mount. Additional components may be required from the AP manufactur-
er.
Utilice el clip de montaje en T de la barra del fabricante para conectar el
AP al soporte de la barra en T. Es posible que se requieran componen-
tes adicionales del fabricante de AP.
4
Use minimum 12-gauge support wire (included) to support the access
point enclosure independently of the ceiling grid. Attach one end of the
wire to the support wire tabs located along the edge of the back box and
the other end to a permanent supporting structure within the ceiling such
as a ceiling joist.
Use un cable de soporte mínimo de calibre 12 (incluido) para soportar el
recinto del punto de acceso independientemente de la rejilla del techo.
Conecte un extremo del cable a las pestañas del cable de soporte ubi-
cadas a lo largo del borde de la caja posterior y el otro extremo a una
estructura de soporte permanente dentro del techo, como una viga del
techo.
**IMPORTANT** - This is an important safety feature that
could prevent human injury or damage to the access point should
the unit become dislodged from the ceiling.
**IMPORTANTE** - Esta es una característica de seguridad
importante que podría evitar lesiones humanas o daños al punto de
acceso si la unidad se desaloja del techo.
©1999-2020 Oberon Incorporated. All rights reserved.
EPN 1937 - Rev. 2/28/2020
5
Run the data cable through the conduit connectors located on sides of
the enclosure backbox. Pull the data cable through the conduit connector
far enough to allow attachment to the access point (8" - 10"). Snap the
firestop grommet on to the cable and slide it inside the conduit connect-
or.
Pase el cable de datos a través de los conectores de conducto ubicados
a los lados de la caja posterior del gabinete. Pase el cable de datos a
través del conector del conducto lo suficiente como para permitir la co-
nexión al punto de acceso (8" - 10"). Coloque la arandela cortafuegos en
el cable y deslícela dentro del conector del conducto.
6
Plug the equipment cord into the surface mount box. If a surface mount
box was not used, plug the data cable directly into the access point.
Close and lock the access door.
The installation is now complete.
Conecte el cable del equipo a la caja de montaje en superficie. Si no se
utilizó una caja de montaje en superficie, conecte el cable de datos di-
rectamente al punto de acceso.
Cerrar y bloquear la puerta de acceso.
La instalación está completa.
Mounting Solutions for WiFi Access Points

Publicidad

loading

Este manual también es adecuado para:

1052-dome