Descargar Imprimir esta página

Operational Summary - Bushnell Pro 1M Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
GETTING STARTED

OPERATIONAL SUMMARY

While looking through the Pro 1 M™, depress the power button once to activate the Vivid Display. Place the aiming
circle (located in the center of the field of view) upon a target at least 5 yards away, depress and hold the power button
down until the range reading is displayed near the bottom of the in-view display. Crosshairs surrounding the aiming
circle indicate that the laser is being transmitted. Once a range has been acquired, you can release the power button.
The crosshairs surrounding the aiming circle will disappear once the power button has been released (i.e. the laser is
no longer being transmitted).
Note: Once activated, the display will remain active and display the last distance measurement for 10 seconds. You can depress the power button again
at any time to distance to a new target. As with any laser device, it is not recommended to directly view the emissions for long periods of time with
magnified lenses. The maximum time the laser is transmitted (fired) is 10 seconds. To re-fire, press the button down again.
ADJUSTING THE EYEPIECE
Your Pro 1 M™ is constructed with a twist-up eyepiece designed for comfort and to exclude extraneous light. For users
without eyeglasses, rotate the eyecup counter clockwise while pulling up until it locks into the fully "up" position. The
Pro 1 M™ provides extra-long eye-relief. If you wear glasses, make sure the eyecup is in the down position as this will
bring your eye closer the eyepiece lens allowing you to see a full field of view. To lower the eyecup from the full "up"
position, rotate clockwise while pushing down slightly. It is also possible to set the eyecup to positions "In between",
fully up and full down, which may suit some individuals better. The Pro 1 M™ is also equipped with an adjustable
eyepiece (+/- 2 Diopter Adjustment) that allows one to focus the VDT™ display relative to the image. Simply rotate
the diopter setting until the VDT™ is in focus.
6
VIVID DISPLAY INDICATORS
Your Pro 1 M™ Vivid Display™ incorporates the following illuminated indicators:
PinSeeker Slope & E.S.P
PinSeeker™ Indicator (1)
Aiming Reticle (2)
Battery Life Indicator (3)
4
Active Laser (4)
Distance Displayed in Yards/Meters (5)
3
BATTERY LIFE INDICATOR
Battery Indicator:
Full charge
2/3 battery life remaining
1 /3 battery Life remaining
Battery Indicator Blinks - Battery needs to be replaced and unit will not be operable.
INSERTING THE BATTERY
Remove the Posi-Thread™ battery door by lifting the battery door tab and then rotating counter clockwise. Insert a
(CR 1 23)
3-volt lithium battery into the compartment negative end first, then replace battery cap.
Note: It is recommended that the battery be replaced at least once every 6 months.
ACTIVE LASER
Crosshairs surrounding the aiming circle indicate that the laser is being transmitted. Once a range has been acquired,
you can release the power button. The crosshairs surrounding the circle will disappear once the power button has been
released (i.e. the laser is no longer being transmitted).
103
PinSeeker & E.S.P "Play-As"
2
1
5
PinSeeker beyond E.S.P range— 20196, 205107, 205108
7

Publicidad

loading

Este manual también es adecuado para:

205107205108