WATER CONNECTIONS (DEALER)
THE STOVE MUST NEVER BE RUN WITHOUT WATER IN THE SYSTEM.
"WATERLESS" IGNITION DAMAGES THE STOVE.
Plumbing must be carried out by qualified staff authorized to issue declarations of conformity in compliance with Italian law No.
46/90. In other countries, refer to local laws and regulations.
Practical NOTE
When connecting outlets, inlets and drainage (see page), do it in such a way that the stove may be easily moved in the future.
Water treatment
Add antifreeze, scale inhibitors and corrosion inhibitors. If the top-up water has a hardness greater than 35°F, use a water softener
to reduce it. For suggestions, refer to Italian standard UNI 8065-1989 (Water treatment in domestic heating systems). A few possi-
ble indicative system designs are shown below.
Boiler-stove system as unique heat source.
This layout is purely indicative. Have a plumber design and install the system.
LEGEND
AF:
AL:
C:
GR:
MI:
P:
RA:
RI:
S:
ST:
TS:
V:
VA:
Vec:
VSP:
VST:
- 26
-
Cold Water
Water supply
Filling/Topping up
Filling unit
Outlet to system
Pump (circulator)
Radiators
Inlet from system
Drain
Temperature Detector
Boiler-Stove
Ball valve
Automatic bleed valve
Closed Expansion Tank
Safety Pressure Valve
High Temperature Drainage Valve
Internal stove components Manifold