Installer setup
Setup function
0502
Furnace filter
alert options
0510
Humidifier pad
change alert
0520
UV lamp change
alert
0530
Adaptive Intelligent
Recovery™
0540
Program periods
0580
Compressor off
time (min.)
0600
Heat temperature
range stop
0610
Cool temperature
range stop
0640
Clock format
0650
Extended fan
timer (heat)
0660
Extended fan
timer (cool)
0670
Keypad lock
0680
Heat temperature
control
0690
Cool temperature
control
0700
Temperature
display offset
0701
Humidity
display offset
0710
RESET
* Humidifier Pad replacement will be displayed in the user interface as run
time days if ISU 372 is set to 1 or 3 and calendar days if ISU 372 is set to 0.
Settings & options (factory default in bold)
0
Timer counts Heat & Cool run time
1
Timer counts Cool run time only
E
Auto Discover
*
0
Off
1
90 calendar days or 30 days run time
2
180 calendar days or 60 days run time
3
365 calendar days or 90 days run time
E
Auto Discover
0
Off
1
365 calendar days (1 year)
2
730 calendar days (2 years)
**
1
On
0
Off
4
4 program periods (Wake, Leave, Return, Sleep)
2
2 program periods (Wake, Sleep)
5
5 minute compressor off time
[Other options: 0 to 4 minutes]
90
Max. heat temperature setting is 90°F (32°C)
[Other options: 40 to 90°F (4°C to 32°C)]
60
Min. cool temperature setting is 60°F (15°C)
[Other options: 60-99°F (15°C to 37°C)]
12
12-hour time (i.e., "3:30 pm")
24
24-hour time (i.e., "15:30")
0
Off
[Other options: Fan runs for 30, 60, 90 or 120 seconds after call for
heating ends]
0
Off
[Other options: Fan runs for 30, 60, 90 or 120 seconds after call for
cooling ends]
0
Keypad unlocked (fully functional)
1
Partially locked (access to temperature settings only)
2
Fully locked
2
Standard temperature control (recommended)
1
Choose if room is warmer than set temperature
3
Choose if room does not reach set temperature
2
Standard temperature control (recommended)
1
Choose if room is cooler than set temperature
3
Choose if room does not reach set temperature
0
Thermostat displays actual room temperature
[Other options: -3°F to +3°F offset (-1.5°C to 1.5°C)]
0
Thermostat displays actual room humidity
[Other options: -5% to +5% offset]
0
No reset
1
Reset installer options & program schedule to factory default (only