TERMINALS
+~
Power positive (12Vac or 12Vdc)
-~
Power negative (12Vac or 12Vdc)
H
Timeslots
A2
Hall door opener relay 2
A1
Hall door opener relay 1
S1
Common contact relay 1
S3
Normally open contact relay 1
S2
Normally closed contact relay 1
S4
Common contact relay 2
S6
Normally open contact relay 2
S5
Normally closed contact relay 2
GND
Ground
PROGRAMMING
MASTER PASSWORD
PROGRAMMING PROCEDURE
The master password is required to access device
confi guration programming mode.
Power the device.
Press the programming switch next to the terminal
board three times in 6 seconds.
The device will beep three times and the red LED
will light up for confi rmation.
Enter the password code (from 3 to 8 digits).
Press
to confi rm.
The device will beep three times to confi rm. The
red LED will go out and the device will switch to
normal operation.
To modify the master password, if
required, disconnect the device from
the power supply for at least 5 seconds
and repeat the procedure described
above.
ACCESSING PROGRAMMING
MODE
Programming mode may be used to confi gure
operation of the device and to save or edit access
codes.
Press
X
.
Enter the password and press
The device will beep three times and the red LED
will light up for confi rmation:
programming mode.
Either hold X pressed for at least three second or
leave the device inactive for more than 30 seconds
to quit programming mode.
DS1148-003B
.
the device is in
RELAY OPTIONS
PROGRAMMING PROCEDURE
Access programming mode.
Enter the confi guration code nn a b ss where:
nn is the relay to be confi gured; possible values
are:
31 = relay 1
32 = relay 2
a
defi nes whether the code needs to be confi rmed
by pressing the button
values are:
1 =
relay activation entering the code only
2 =
relay activation entering the code and
pressing the button
b
defi nes the relay activation mode; possible
values are:
1 = monostable activation
2 = toggle activation
ss defi nes the activation time expressed in
seconds; possible values are:
00 = 200ms (set this value for toggle
operation)
01 = 1 second
..
99 = 99 seconds
Press
to confi rm.
The device will beep three times and the red LED
will blink three times.
If the entered code is wrong, the device will beep
twice in rapid succession and wait for the correct
code to be entered.
ACTIVATION CODE STORAGE
PROCEDURE
Access programming mode.
Enter confi guration code nn xxxxxxxx where:
nn
defi nes the code memory location;
possible values from 01 to 22.
xxxxxxxx activation code (from 3 to 8 digits).
Press
to confi rm.
Defi ne the number of relays to be activated with the
code shown:
1 = relay 1
2 = relay 2
Press
to confi rm.
The device will beep three times and the red LED
will blink three times.
If the entered code is wrong, the device will beep
twice in rapid succession and wait for the correct
code to be entered.
or not; possible
to confi rm.
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sinthesi1158/461148/46

Tabla de contenido