The appliance must be installed only by a qualified
person in compliance with the instructions provided.
The manufacturer declines all responsibility for improper
installation which may harm persons and animals and
damage property.
Important: The power supply to the appliance must be
cut off before any adjustments or maintenance work is
done on it.
Installation of Built-in Ovens
In order to ensure that the built-in appliance functions prop-
erly, the cabinet containing it must be appropriate. The
figure below gives the dimensions of the cut-out for instal-
lation under the counter or in a wall cabinet unit.
N.B.: Installation in compliance with the consumption declaration
In order to ensure adequate ventilation, the back panel of
the cabinet unit must be removed. Installing the oven so
that it rests on two strips of wood is preferable. If the oven
rests on a continuous, flat surface, there must be an ap-
erture of at least 45 x 560 mm.
Instalation
The panels of the adjacent cabinets must be made of heat-
resistant material. In particular, cabinets with a veneer ex-
terior must be assembled with glues which can withstand
temperatures of up to 100 °C.
In compliance with current safety standards, contact with
the electrical parts of the oven must not be possible once
it has been installed.
All parts which ensure the safe operation of the appliance
must be removable only with the aid of a tool.
To fasten the oven to the cabinet, open the door of the
oven and attach it by inserting the 4 wooden screws into
the 4 holes located on the perimeter of the frame.
Electrical Connection
Those ovens equipped with a three-pole power supply
cable are designed to operate with an alternating current
with the voltage and frequency indicated on the data plate
(located on the appliance) and in the instruction manual.
The wire for earthing the appliance is yellow-green in col-
our.
Fitting on a Power Supply Cable
Opening the terminal board:
•
Using a screwdriver, prise on the side tabs of the ter-
minal board cover;
•
Pull open the cover of the terminal board.
To install the cable, proceed as follows:
•
Remove the wire clamp screw and the three contact
screws L-N-
•
Fasten the wires beneath the screwheads using the
following colour scheme: Blue (N) Brown (L) Yellow-
Green
•
Fasten the supply cable in place with the clamp and
close the cover of the terminal board.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indi-
cated on the data plate. When connecting the cable di-
rectly to the mains, install an omnipolar circuit-breaker with
a minimum contact opening of 3 mm between the appli-
ance and the mains. The omnipolar circuit breaker should
be sized according to the load and should comply with
current regulations (the earth wire should not be inter-
19
N
L