RED LIGHT (Figure 15C)
A glowing red light indicates the auto-dim temperature is exceeded.
A blinking red light indicates the shutdown temperature has been exceeded. (see section 7.4)
A glowing red light indicates the auto-dim temperature has been exceeded in the past. (see section 7.4)

7.4 Interpreting Display Messages

SENSOR DISCONNECTED
The message "sensor disconnected" appears when the temperature sensor is not plugged in. All devices
connected to the controller are deactivated. Plug in the missing sensor to resolve.
SENSOR FAILURE
If the message "sensor failure" appears, the sensor is defective. All devices connected to the controller are
deactivated. The controller must be reset. Follow these instructions to reset:
1. Replace the temperature sensor.
2. Hold the BACK button for 3 seconds.
CONTROLLER OVERLOAD
If the message "controller overload" appears, the main channel has been overloaded. The blue LED indicator
behind the overloaded channel will also start flashing. An overload may occur when the wiring connected
to the main channel of the controller has short circuited. All devices connected to the controller will be
deactivated. The controller must be reset. Follow these instructions to reset:
1. Search for faulty wiring or contacts and replace it.
2. Hold the BACK button for 3 seconds.
AUTO-DIM
When the auto-dim temperature has been exceeded, the message "auto-dim" will appear on the display.
The red light will also flash. The flashing will continue until the temperature drops 0.5°C/0.9°F below the
auto-dim temperature for at least 30 seconds.
A glowing red light indicates the auto-dim temperature has been exceeded in the past. To resolve a glowing
red light, hold the BACK button for 3 seconds to reset the warning.
TEMP ALARM
When the shutdown temperature has been exceeded, the message "temp alarm" will appear on the display
and the red light will flash rapidly. All devices connected to the controller are deactivated. The controller
must be reset. Follow these instructions to reset:
1. Ensure the temperature of the room is below the shutdown temperature. If the temperature is still
above the shutdown temperature, the controller cannot be reset.
2. Hold the BACK button for 3 seconds to reset the controller.
8. MAINTENANCE, REPAIR AND DISPOSAL
8.1 Maintenance and Repair
WARNING! Do not open or disassemble the controller. It contains no serviceable parts. Opening the
controller will void its warranty and may cause electrical shock.
The controller may be cleaned with a soft, dry cloth.
Note: Do not use acids, solvents, abrasives or other aggressive substances to clean the controller as this may
cause damage.
8.2 Disposal
ATTENTION: THIS PRODUCT CONTAINS A BATTERY. IT MUST BE DISPOSED OF PROPERLY.
This product may not be discarded as household waste. Dispose of the equipment through a recycling
center that handles electronics and electrical appliances within your territory.