Hold field no. 6 for a while (fields 5 and 6 start to flash).
By pressing fields + or – you can set the number of vacation days shown in field no.
5.
By pressing field no. 6 again, or when field no. 6 stops flashing, the set number of
days is stored.
If you set the value to 0, then the heat pump will resume its normal operating mode
after confirming the setting, and illumination of field no. 6 will turn off.
After the set number of days has elapsed, the heat pump returns to the normal
mode and illumination of field no. 6 turns off.
Setting the TIMER mode
In the TIMER operating mode, you can set the times when the heat pump will start
and stop. For each timer combination you can set up to three time periods in which
the heat pump will not heat the water.
a) Setting the timer combinations
Hold field no. 11 for a while (fields 7 and 11 start to flash).
By pressing fields + or – choose among three timer modes of operation:
- Timer mode of operation of the heat pump for the entire week (numbers 1-7 flash
in field no. 7),
- Timer mode of operation of the heat pump for Monday to Friday and Saturday to
Sunday (numbers 1-5 and then 6 and 7 flash in field no. 7),
- Timer mode of operation of the heat pump for each day at a time (individual
numbers 1-7 flash in field no. 7). Press field + or – to select each day of the week.
To set the time, press field no. 12.
On the field no. 5, the text 1OF appears and field no. 12 starts to blink.
By pressing fields + or – set the time of shutdown.
Press field no. 12 again.
On the field no. 5, the text 1ON appears and field no. 12 starts to blink.
By pressing fields + or – set the time of start-up.
By pressing field no. 12 again, you can use the above procedure to set the second
and third period.
If you do not want to set the second and third periods, confirm the setting by
pressing field no. 11 or wait for field no. 12 to stop flashing and the setting to be
saved automatically.
To set the second and third periods, set the start and end of periods 2 and 3 and
confirm the setting following the procedure described above by pressing field no. 11
or wait for field no. 12 to stop flashing and the setting to be saved automatically.
To set the timer operating mode "for each day of the week" or "for the period from
Monday to Friday and from Saturday to Sunday", set all 3 time periods following the
procedure described above.
b) Activation, deactivation of timer
By pressing field no. 11, you can activate the set timer mode.
The heat pump heats the water in the ON periods (to the set temperature) and in
the OFF periods, it does not heat the water.
15