Diagrama de Cableado de Sistema AC (60K 3 fase)
OFM
TYPE
ADJ
ON
0
ON
0
IFM
1
1
1 2 3
1 2
A B C
D E
NOTES:
1: Remove the red lead from
240V terminal and then connect the red lead to
* Default factory settings.
2: switch
TYPE and
ADJ
choose different model and air volume . please refer to the user manual to choose
3:
W2 wire is not provided in some models and
B is only for HP unit .
4:
MANUAL DEFROST
and
JUMP
is unavailable for AC unit.
PLUG PLATE
T1
T2
T3
CC
L3 L2 L1
C
YOUT
LED1
TDC
O FAN
CN8
0 1
CN18
0 1
CN14
JUMP
RED
CN18
0
BLACK
L1
MANUAL DEFROST
T4
C RV CN15
T
3
208V terminal on the transformer for 208 volts.
0
or
GROUND
L1
L2
R
C
WHITE
D
GREEN
G
YELLOW
Y
BLUE
B
W2
WHITE/BLACK
6
1
5
4
CN2
3
2
1
CN16
1 .
CC
COMPRESSOR CONTACTOR
COMP COMPRESSOR
TDC
TIME DELAY CONTROL
T4
10K RESISTANCE.
T3
10K RESISTANCE.
HPC
SHORT CIRCUIT WIRE
LPC
SHORT CIRCUIT WIRE
OFM
OUTDOOR FAN MOTOR
RC 1
COMPRESSOR RUN CAPACITOR
RC 2
OUTDOOR FAN MOTOR RUN CAPACITOR
GND
GROUND CHASSIS
IFM
INDOOR FAN MOTOR
LINE VOLTAGE
FACTORY STANDARD
FIELD INSTALLED
FACTORY OPTIONAL
LOW VOLTAGE
FACTORY STANDARD
FIELD INSTALLED
FACTORY OPTIONAL
USE COPPER CONDUCTORS ONLY
WARNING
CABINET MUST BE PERMANENTLY
GROUNDED AND ALL WIRING TO CONFORM TO
I.E.C, N.E.C, C.E.C, C.L.C, AND LOCAL CODES AS APPLICABLE
REPLACEMENT WIRE MUST BE THE SAME GAUGE AND
INSULATION TYPE AS ORIGINAL WIRE.
STEADY ON = NORMAL OPERATION
0
OFF = TDC FAILURE
1 FLASH = T3 SENSOR FAILURE
1
2 FLASH = T4 SENSOR FAILURE
2
3 FLASH = LPC OPEN
3
4 FLASH = POWER PHASE FAILURE
4
5FLASH = IFM FAILURE
5
6FLASH = HPC OPEN
6