Remote Control Handset - Robin WINDY PRO 900 Instrucciones De Instalación E Utilización

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
Press LED button 5 to obtain the boost position for maximum effect and the LED C will illuminate to
confirm fan is switched 'ON'.
C – COMPLEMENTARY INSTRUCTIONS
Automatic pre-set stop for the boost speed after 10 mn.
To obtain the best performance it is advisable to switch 'ON' the cooker hood a few minutes (in the
boost setting) before you start cooking and you should leave it running for approximately 10 minutes
after finishing.
Press LED button 5 to switch 'OFF' the fan motor immediately.
Indication of saturation of the metal grease filters
After 100 hours use, one quick flash of the LED F will indicate that you must clean the metal grease
filters. (See chapter on 'Maintenance').
This indication is not available when the fan motor is switched OFF.
Indication of saturation of the active charcoal filter
After 200 hours use, two quick flash of the LEDS F & C will indicate that you must replace the active
charcoal filter and clean the metal grease filters. (See chapter on 'Maintenance').
To reset the 200-hour timer the motor and lights must be switched 'OFF'.
Push the LED button '+' for 10 seconds.
One flash of the LED lights F and C = function is switched 'OFF'.
Two flashes of the LED lights F and C = function is switched 'ON'.
To reset the 100 hours timer back to zero requires the motor and lights must be switched 'OFF'; then
and proceed as follows:
Press the LED button '+' for 3 to 4 seconds and the LED lights F and C will flash to confirm the programme
has been reset to zero.
Instructions for replacing the active charcoal filter are given in the chapter on 'Recycling'.
Setup Process
Modification: How to adjust the internal microprocessor data to suit the type of motor fitted to
this appliance and the supply frequency of 50 or 60 Hz..
1 - Disconnect the cooker hood from the mains supply.
2 - Push the button 0/1 MOTOR.
3 - Reconnect the mains supply while pushing the button 0/1 MOTOR for at least 2 seconds.
4 -
Slacken the button 0/1 MOTOR (the Leds flash for about 3 seconds : capacity's
confirmation SETUP
5 -
During the flashing time select the motor type used while pushing one of the 5 buttons
according to the following board:
BUTTON 0/1 Light
BUTTON 0/1 Motor
BUTTON Speed ( - )
BUTTON Speed (+ )
BUTTON Intensive speed

REMOTE CONTROL HANDSET

Caution, the remote control must be fitted with standard LR03-AAA size 1.5V zinc-carbon alkaline bat-
teries as illustrated Fig. 8. These batteries should give a long life and constant discharge throughout
their life.
These batteries must be disposed of properly and could explode if damaged or exposed to heat.
PROCESS).
:
Motor FABER 8/28 & 8/50 220-240 V AC / 50 Hz.
:
Motor FABER 8/28 & 8/50 220-240 V AC / 60 Hz.
:
Motor EBM PRO 220-240 V AC / 50 Hz.
:
Motor EBM PRO 220-240 V AC / 60 Hz.
:
Motor K40 & K50 220-240 V AC / 50 Hz.
GB
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Windy pro 1000Windy pro 1200

Tabla de contenido