Specifications
325
Electrical Specifications
AC Current (Jaw)
Range
Hz
Resolution 323 . . . . . . . . 0.1 A
Accuracy 323, 325 . . . . 2.0 % ±5 digits (45 – 65 Hz)
Note: Add 2 % for position sensitivity.
DC Current with Jaw (325)
Range
Resolution
Accuracy
AC Voltage
Range
Resolution
Accuracy (45 – 400 Hz) . . 1.5 % ± 5 digits
DC Voltage
Range
Resolution
Accuracy
Resistance
Range
Resolution
Accuracy
Continuity Beeper
AAA
Capacitance (324, 325)
Range
Resolution
Accuracy
Frequency with Jaw (325)
Range
Resolution
Accuracy
Trigger Level . . . . . . . . . . 5 to 10 Hz, ≥10 A
Contact Temperature (324, 325)
Range
Resolution
323 . . . . . . . . 400.0 A
Accuracy
324, 325 . . . . (40.00, 400.0) A
Note: Temperature uncertainty (accuracy) does not include error of
324, 325 . . . . (0.01, 0.1) A
the thermocouple probe.
2.5 % ±5 digits (65 – 400 Hz)
Mechanical Specifications
324 . . . . . . . . 1.5 % ±5 digits (45 – 400 Hz)
Size (L x W x H) . . . . . . . . . . (207 x 75 x 34) mm
Weight
323 . . . . . . . . . . . 265 g
324 . . . . . . . . . . . 208 g
. . . . . . . . . . . (40.00, 400.0) A
325 . . . . . . . . . . . 283 g
. . . . . . . . . . . (0.01, 0.1) A
. . . . . . . . . . . 2.0 % ± 5 digits
Environmental Specifications
Operating Temperature . . . . . -10 °C to +50 °C
. . . . . . . . . . . 600.0 V
Storage Temp . . . . . . . . . . . . -30 °C to +60 °C
. . . . . . . . . . . 0.1 V
Operating Humidity . . . . . . . . Non Condensing (≤10 °C)
. . . . . . . . . . . 600.0 V
. . . . . . . . . . . 0.1 V
Operating Altitude . . . . . . . . . 2000 meters
. . . . . . . . . . . 1 % ±5 digits
Storage Altitude . . . . . . . . . . . 12,000 meters
EMI, EMC
Electromagnetic
323, 324 . . . . (400.0, 4000) Ω
Compatibility . . . . . . . . . . . . . Applies to use in Korea only. Class A
325 . . . . . . . . (400.0, 4000, 40000) Ω
. . . . . . . . . . . (0.1, 1, 10) Ω
. . . . . . . . . . . 1 % ±5 digits
323 . . . . . . . . ≤70 Ω
324/325 . . . . . ≤30 Ω
. . . . . . . . . . . (100.0, 1000) µF
. . . . . . . . . . . (0.1, 1) µF
Temperature Coefficients . . . . Add 0.1 x specified accuracy for each
. . . . . . . . . . . 1 % ±4 digits
Over Voltage Category . . . . . CAT IV 300 V, CAT III 600 V
Safety Compliance . . . . . . . . EN/IEC 61010-1, Pollution Degree 2
. . . . . . . . . . . 5.0 to 500.0 Hz
. . . . . . . . . . . 0.1 Hz
. . . . . . . . . . . 0.5 % ±4 digits
10 to 100 Hz, ≥5 A
Agency Approvals . . . . . . . . .
100 to 500 Hz, ≥10 A
IP Rating
Batteries
. . . . . . . . . . . . . . -10.0 °C to 400.0 °C
. . . . . . . . . . . . . . 0.1 °C
. . . . . . . . . . . . . . 1 % ±8 digits
≤90 % RH (at 10 °C to 30 °C)
≤75 % RH (at 30 °C to 40 °C)
≤45 % RH (at 40 °C to 50 °C)
(Without Condensation)
Equipment (Industrial Broadcasting &
Communication Equipment) [1]
[1] This product meets requirements for
industrial (Class A) electromagnetic
wave equipment and the seller or
user should take notice of it. This
equipment is intended for use in
business environments and is not to
beused in homes.
degree C above 28 °C or below 18 °C
EN/IEC 61010-2-032
EN/IEC 61010-031:2002/A1:2008
Complies with CAN/CSA-C22.2
No. 61010-1, 2nd edition, including
Amendment 1.,
,
. . . . . . . . . . . . . . IP 30 Per IEC 60529:2001;
Non-operating
. . . . . . . . . . . . . . 2 AAA, NEDA 24A, IEC LR03