INSTALLATION
6.1
GENERAL CONSIDERATIONS
In the following paragraphs there are some
guidelines to follow in order to obtain the maximum
performance of the product purchased.
The following instructions are nevertheless subject
to compliance with any laws and national, regional
and municipal regulations in force in the country
where the product is installed.
In Italy the installation must be carried out by
qualified personnel in accordance with the UNI
10683.
6.2
SAFETY PRECAUTIONS
The responsibility of the works carried out in the
area where the fireplace will be installed falls on the
user; the latter is also entrusted with the execution
of the inspections related to the installation solutions
proposed.
The user must comply with all local, national and
European safety regulations.
The appliance must be installed on floors with
adequate load bearing capacity.
The fireplace removal and installation instructions
are reserved only to specialized technicians. It is
always recommended that users contact our after
sale service to request qualified technicians.
In the case other technicians are involved, it
is recommended to verify their actual abilities.
The installer, before starting assembling or
disassembling the fireplace, must comply with the
safety precautions required by law and in
particular with:
A) do not operate in adverse conditions;
B) must operate in perfect psychophysical
conditions and must check that the personal
protective equipment, are intact and functioning
perfectly;
C) must wear safety gloves;
D) must wear safety shoes;
E) must use electrical insulated tools;
F) must ensure that the area affected by the
phases of assembly and disassembly is free
from obstacles.
6.3
PLACE OF INSTALLATION OF THE PRODUCT
In the product handbook annexed are indicated the
minimum distances with respect to the combustible
materials and articles expressed in cm that must
be respected while positioning the product.
Protect all structures which could ignite if exposed
to excessive heat.
Floors consisting of flammable material such as
for example: wood, parquet, linoleum, laminate or
covered with carpets, must be protected by a flame
retardant base under the stove, of a sufficient size.
The manufacturer declines all responsibility for
any variations in the characteristics of the material
constituting the floor under the protection.
Any wood items (e.g. beams) or in combustible
34
material located in the vicinity of the fireplace should
be protected with a non-combustible material.
Provide a technical space accessible for
maintenance.
Please remember to respect the minimum distance
from flammable materials stated on the id plate of
the tubes used to manufacture the fireplace.
The appliance is provided with wheels for positioning,
paying particular attention to adequately protect the
wood or parquet floors in order to prevent the weight
of the appliance to damage them during movement.
6.4
ASSEMBLY DIAGRAM
In Fig. 6, an assembly diagram is shown in an exemplary
manner, it must not be installed in a shared flue.
A) Seal
B) External air intake (under fire bed)
C) Heat recovery grill
cm2
D) Counter-hood and fireproof load-bearing structure
E) Cladding in ceramic fibre or rock wool with external
aluminium foil
F)
Shield the wooden parts with flame retardant
material
G) Minimum distance between the cladding and
ECOMONOBLOCCO WT 78, 20 mm
H) INLET HEAT EXCHANGE AIR. The minimum
section for the air passage must be not less than
842 cm2
• For a correct installation, the smoke channel between
the ECOMONOBLOCCO WT 78 and the chimney should
be made in airtight sealing, with material suitable for high
temperatures, between all the union joints.
• If the ECOMONOBLOCCO WT 78 is to be installed on
a flue previously used by other fireplaces it is necessary
to carry out a thorough cleaning to prevent anomalous
operations and prevent the fire of unburned substances
which are deposited on the inner walls of the same.
• Improper installation can affect the safety of the
equipment.
• The cladding must be made of fireproof material.