WARNI NG: The following instr uctions contain
impor tant safety infor mation
• Prior to installation please read carefully these instructions
(especially the " Safety Notices" ).
• Keep these instructions to consult them after installation if
necessary.
• Unsuitable application or wrong installation may result in a loss
of system operating functions and consequently in damages
or/and injuries.
• Only original parts and fittings shall be used to install the
actuator.
• Electronic stop in the end stroke and intermediate positions.
• Designed for applications on top hinged windows, domes and
louvres.
• Possibility of parallel connection to operate more windows
simultaneously.
• The actuator is for internal use only.
• The working temperature of actuators are: -10°C +60°C with
maximum relative humidity 60%.
SAFETY NOTI CES
• The actuator shall be installed by qualified personnel.
• Prior to installation make sure that:
- the actuator performances comply with the estimated
application
- window profiles and fittings are suitable to the stresses caused
by the actuator
- window fittings (hinges) and absence of obstacles allow
complete opening
- bottom hinged windows are provided with side checks
- the existing electric systems comply with the regulations in
force
- power supply features are those indicated in the actuator
specifications
• Before connecting the actuator to power supply make sure it has
been turned off to avoid electrocution.
• An omnipolar switch shall be provided in the supply mains
(according to CEI EN 60335-1).
• I n case the window is accessible at a height of 2,5 m at least
provide the system with an emer gency switch off and/or
with additional safety devices.
• Make sure the supply cable is not subject to stress when
operating.
• When assembling and disassembling the actuator, take proper
precautions to avoid accidental closing of the window which
might cause injuries to people (impact-squashing-cutting-
shearing).
• By feeding the actuator make sure that operation is regular and
that opening and closing end-stroke switches operate correctly.
• When operating the actuator follow the following instructions:
- prevent liquids penetration in the actuator.
- do not approach moving parts until they have come to a
complete stop.
- at least once a year check at sight for damages or wear in the
supply cable.
- to open the window in case of power failure, remove the split
pin (par t 6)
- do not car r y out any intervention on the actuator , do not
remove or disassemble par ts of the actuator : in case of
malfunction or damaged cable contact " UCS" .
Doc. 80486P – Rev. 15/04/13
English
I NSTAL L ATI ON I NSTRUCTI ONS OF SI NGL E
The actuator can be mounted using one of the following kits:
• (Fig. 1) sliding bracket-kit (Par t. No 40235F): the dovetail
guide allows bracket " 1" to be secured to the actuator along its
ntire length.
• (Fig. 2) front-back fitting bracket (Par t. No 40234E) : bracket
" 4" is secured through the holes placed on the actuator
top/bottom.
WARNI NG:
• Check allignement between sliding bracket (or front-back fitting
bracket) and connector " 3" for the tie–rod " 2" installation.
• Adjust closing end stroke by means tie-rod " 2" .
• Follow diagram for electric connection.
I NSTAL L ATI ON OF DUAL RACK
Dual Rack is mounted using the front-back fitting bracket (not
supplied) (Fig. 3-4):
Mount the motorized actuator with its bracket " 4" secured to the
holes placed on the front/back of the actuator.
Fit connecting rod into the shaft cf the motorized actuator.
Fit connecting rod into the shaft of the non-motorized actuator
and secur e it with cotter pin ( included).
Mount the non-motorized actuator with its bracket " 4" secured
to the hoIes placed on the front/back of the actuator.
WARNI NG:
- Do not use the sliding bracket-kit to mount Dual Rack – Double
Rack
- The distance between centers of front-back fitting brackets is to
be D+40 mm
- Check that end bracket " 4" and connector " 3" (securing the tie
rod " 2" ) are aligned.
- Adjust end stroke by means cf tie rod " 2" .
- Follow diagram for electric connection.
Ultraflex Control Systems S.r.l. products are guaranteed, for a
period of two year s from the manufacture date, against defects in
material and workmanship.
Alleged defective products returned, freight prepaid, within the
above said term, will be repaired or replaced free of charge, at our
option, if found effectively below our quality standards.
This guarantee does not cover other claims for direct or indirect
damages.
In particular, we decline liability and exclude guarantee (except
for what stated above) if improper installation or misuse should
result in a failure of our products.

CORRECT DI SPOSAL OF THI S PRODUCT

The correct disposal of your old appliance will help prevent
potential negative consequences for the environment.
Pag 5 di 8
ACTUATOR
DOUBL E RACK
GUARANTEE
Dis. 13460/d