6. Connecting electricity
■
Connect the spark ignition cables to a 12V DC battery using appropriate connectors.
7. After installation
■
Fix a warning label next to the unit that meets the requirements of EN721, Annex A;
■
Test all gas piping and connections and make sure they do not leak;
■
Check the pressure of the gas when all connected gas appliances are in use simultaneously.
The gas pressure may not rise or fall by more than 2.5mbar relative to the nominal value;
■
Ensure that all packaging materials have been removed.
8. Technical specifications
Table 1: Burner specifications
Auxiliary Burner
Semi-Rapid Burner
Rapid Burner
Total
Table 2: Dimensions and weight
Dimensions
mm
Appliance Weight
Spark ignition
SHB353
Gas input
Injector
kW
g/hr
1.0
72
1.5
107
2.5
179
5.0
358
SHB353
H
W
101
660
8.5kg
12V DC
SCU353
Gas input
mm
kW
0.52
1.0
0.61
1.5
0.77
2.5
5.0
SCU353
D
H
410
160
10.7kg
12V DC
EN
Injector
g/hr
mm
72
0.52
107
0.61
179
0.77
358
W
D
980
410
7