Specific Information
• Make sure DLP can rotate 360° and articulate 110° without interfearing
with other parts.
• DLP should be tightened to torque according to the relevant table
(+/- 10%). In case of turning movements the recommended torques
must be checked regularly.
• Adjust to the direction of the pull before attaching to the lifting means.
0°
• All fittings connected to the DLP should be free moving. When
connecting and disconnecting the lifting means (wire ropes, chain
slings, round slings), pinches and impacts should be avoided. Damage
to lifting components caused by sharp corners should also be avoided.
• To prevent unintended dismounting through shock loading, rotation
or vibration, thread-locking fluid such as Loctite (depending on the
application, please refer to the manufacturer's instruction) should be
used to secure the bolt.
• Do not fit with larger hook than DLP can accomodate.
0°
Rotation around screw axls when loaded at 0-15 ° is not allowed.
110°
15°