The maintenance of the machine must be perfor-
med by qualified staff, according to the instructions
in this manual. Disconnect the pneumatic/electric
supply before performing any maintenance or
repair operations.
9.1. EXTRAORDINARY MAINTENANCE
Extraordinary maintenance operations should only
be performed by specialized staff: contact the
manufacturer for any extraordinary maintenance
required.
Extraordinary
regards the breakage of machine components.
9.2. GENERAL CLEANING OF THE MACHINE
Every week give an overall clean to the machine,
using solvent and a brush or a spatula if especially
stubborn layers of paint have deposited.
Periodically check that the safety devices are
functional and undamaged.
Any incrustations must be removed from the drains
and control valves regularly.
9.3. CLEANING OF THE SPRAY-JETS
Every 3 weeks, clean and drain off the spray-jets
placed inside the automatic washing tank then
proceed as follows:
- Unscrew all the washing nozzles from the relative
10.1. EXPECTED USE
The S25 machine is a completely pneumatic system
that is used for the manual washing of parts that are
dirtied with water-based or solvent-based paint.
The S25 machine is intended for use by qualified
staff.
By the term "qualified", one means staff that have
been instructed and trained by the employer on the
use of the machine and the risks that this use may
incur (Art. 22, Paragraph VI,Title III of Legislative
Decree 626/94 on the obligation of staff training
when introducing new working systems).
In particular, the users must also be instructed based
on this user and maintenance manual and the
machine must only be used for the production for
which it is suited, as indicated in the manual.
These obligations are also required for the opera-
tors involved in the transport, installation, mainte-
nance and dismantling of the machine, each dedi-
9. MAINTENANCE AND CLEANING
maintenance
usually
10. SAFETY INSTRUCTIONS
- 16 -
pipes.
- Fully immerse the nozzles soiled with paint in a
basin full of solvent and leave to soak for 1 hour.
- In the meantime run an empty wash cycle for
approx. 1 minute, this must be done without the
nozzles on the spider so as to clean the pipes of the
4 nozzles from any paint deposits.
- After the nozzles have soaked for an hour in the
solvent use the air gun to blow the washing nozzles
from the outside (fluid exit side) inwards (side
screwing onto the pipe).
9.4. CLEANING INSIDE THE AUTOMATIC
WASHING TANK
To make easy cleaning inside the automatic
washing tank, you can completely remove the
washing spray-jet device by unscrewing the central
fixing nut (nº15).
9.5. CLEANING SUCTION FILTERS
Every 2 weeks, clean the suction filter present on
the suction pipe of the machine then proceed as
follows:
- Unscrew the suction filter from the relative pipes.
- Fully immerse the filter (soiled with paint) in a basin
full of solvent and leave to soak for 1 hour.
- After soaking for 1 hour, use the air gun to blow
the filter.
- Screw the suction filters onto the relative pipes.
cated to his own competences.
Given that this is a complex machine and its use is
only allowed by instructed and trained staff, access
to the area belonging to the system is forbidden to
those who have not received the necessary training
by the employer.
10.2. WARNING PICTOGRAM
The warnings, legal obligations and the prohibi-
tions, which must be followed in order to operate
safely and to prevent accidents, are shown on the
adhesive labels applied to the S25 machine.
- Read the instruction manual before
operating with the unit.
- Electrostatic electricity.
- Avoid near souces.