Warning!
The Vac-Blower must not be used or switched on until it has been fully assembled.
7.1 Assembly Intake/ Air outlet tube (Pic.2 and 3)
Press the button (2.1) and slide the air duct (2.2), the air duct can be adjusted based on user
height, adjust the height up to 300 mm maximum, 30 mm is a height.
7.2 Fitting the debris collection bag (Pic.4 and 5)
Before fitting the debris collection bag ensure that the Vacuum/Blow selector lever operates
smoothly and that it is not obstructed by debris from the previous use.
When users install the collection bag: turn the support (4.1) frame into the correct position
of housing and make sure the support (4.2) lock in holding fixture (4.3).
When users dismantle the collection bag: press the interlock (5.1) to release, if the support
has been released, the user must carry the bag's weight alone.
Attention: switch off the vacuum until at the handle and pull the plug firstly.
7.3 Fitting the shoulder harness (Pic.6)
The Vacuum-Blower is provided with a shoulder harness (6.1) this is attached to the top of
the main body of the Vacuum-Blower as shown (6.2). The shoulder harness is provided to
reduce fatigue and aid comfort when using the Vacuum-Blower. Never carry the belt
diagonally over shoulder and chest. Wear the strap only on one shoulder, in this way you can
remove the device in case of danger fast.
7.4 Before Starting (Pic.7)
Connect the mains cable with the tool's plug and secure it with the strain relief bracket (7.1)
as shown in Fig 7.
Only connect the device to a power source that is protected via a residual current protective
device (RCD) with a maximum release current of 30 mA.
8. OPERATION
Note: The Vacuum-Blower can be started only with mounted collection bag!
8.1 Starting the Vacuum-Blower (Pic. 8, 9 and 10)
To start the Vacuum-Blower ensure that the intermediate suction/blower tube is fitted
correctly.
Warning! Before selecting either the Vacuum or Blow function ensure that the selector lever
operates smoothly and that it is not obstructed by debris from the previous use. Select either
the Vacuum or Blow function using the selector lever on the side of the machine (8.1) and
press the switch button (9.1). If more power is required slide the speed controller (10.1) from
position "1" to position "Max".
8.2 Stopping the Vacuum- Blower (Pic.11)
To turn off the machine you can simply release the switch (11.1).
19