NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Lamp
Thermostat
LED Power
Switch
Control Knob
(80H MODEL ONLY)
KFA50H/80H Models
NOTICE : The major electrical components of this heater are protected by a safety fuse mounted to the PCB board.
If your heater fails to start, check this fuse first and replace as necessary. You should also check your
power source to insure that proper voltage and frequency are being supplied to the heater.
TO STOP HEATER
1. Turn switch to "OFF" and unplug power cord.
TO RESTART HEATER
1. Wait 10 seconds after stopping heater.
2. Repeat steps under to start heater.
PIGGYBACK POWER CORD
WARNING : SHOCK HAZARD!
• Always cover electric outlet when not in use.
• Don't plug and use a appliance more than 120V/60Hz 5A
current in this outlet.

8. LONG TERM STORAGE OF YOUR HEATER

FUEL TANK DRAIN
1. Drain fuel tank through fuel cap opening.
(For KFA50H/80H Models Only)
2. Remove fuel drain bolt from rear bottom side of fuel tank using 3/4" socket or adjustable wrench and drain.
(For KFA135H/220H Models Only. See Figure 10)
3. Using a small amount of kerosene, swirl and rinse the inside of the tank.
NEVER mix water with the kerosene as it will cause rust inside the tank.
Pour the kerosene out making sure that you remove it all.
IMPORTANT : Do not store kerosene over summer months for use during next heating season.
Using old fuel could damage heater.
4. Reinstall fuel cap. Properly dispose of old and dirty fuel. (For
KFA50H/80H Models Only)
5. Reinstall fuel drain bolt to Fuel tank and tighten firmly using 3/4"
socket or adjustable wrench.
(For KFA135H/220H Models Only. See Figure 10)
IMPORTANT : Before reinstalling the fuel drain bolt, make sure the
6. Store heater in dry well ventilated area. Make sure storage place is free of dust and corrosive fumes.
7. Store the heater in the original box with the original packing material and keep the USER'S MANUAL
with the heater.
Room Temp. Display
Lamp
Thermostat
LED Power
Control Knob
Switch
KFA135H/220H Models
Figure 8. Controls for All Models
seal is on the bolt. If the seal is not used the bolt can
not be installed correctly and the fuel tank will leak.
BTU Control Switch
Btu Control Switch
Fan Guard
Figure 9. Piggyback Power Cord
9
Push to "HIGH"
Push to "LOW"
Cover
KFA80H/135H/220H Models only
Seal
Fuel Drain Bolt
Figure 10. Fuel Drain Bolt
Relief Valve
Outlet