PUL1: close mini-pushbutton
PUL2: open mini-pushbutton
• When pressing PUL1 (close), DL5 lights up and A1 G2-G3 and
A2 G5-G6 cable connectors are enabled.
• When pressing PUL2 (open), DL4 lights up and A1 G1-G3 and
A2 G4-G6 cable connectors are enabled.
DL1
Gate totally or partially open
DL1 - DL3 flashing: STOP contact
o p e n
( e m e r g e n c y
activated)
DL2
Receiving RSD plug-in receiver
radio signal (RUN/OK)
DL3
Radio
code
programming
DL4
Opening relay activated
DL5
Closing relay activated
DL6
Interior safety device contacts
(FT2) closed
6
General connections
DL9
Exterior safety device contacts
(FT1) closed
s t o p
DL10 Pedestrian key command (ST2)
DL11 Total key command (ST1)
DL12 Plug-in receiver key command
(except RSD)
or
operation
DL13 Garage light relay activated
DL14 Power supply
DL15 Electrolock relay activated
DL17 Triac M1 activated
DL18 Triac M2 activated
SW2 Functions during programming (DIP1=ON)
DIP1=ON: programming enabled (DL3 lights up)
DIP1=ON and DIP2=ON: total open/close programming
DIP1=ON and DIP3=ON: pedestrian open/close programming
DIP1=ON and DIP4=ON: total opening radio code programming
DIP1=ON and DIP6=ON: pedestrian opening radio code programming
Turning direction: check operation using the mini-
pushbuttons PUL1 (close) and PUL2 (open). If the
turning direction of any operator is not correct,
interchange the cables connected in cable connectors
G1 and G2 or G4 and G5.
(resistive)
Fuses:
F1 M1 Motor fuse
F2 Electronic fuse
F3 Output fuse 24Vac (315mA)
F4 M2 Motor fuse
A 1 / A 2 o p e r a t o r
connections:
G1/G4 open
G2/G5 close
G3/G6 common,
grey
T: earth
connection
VIVO-M201:
230Vac/50Hz
VIVO-M201M:
125Vac/60Hz
When using a single
operator, connect it to
cable connectors G1, G2
and G3 (operator A1).
– M201: 2,5A (230Vac/50Hz)
– M201M: 6,3A (125Vac/60Hz)
– M201: 0,5A (230Vac/50Hz)
– M201M: 1A (125Vac/60Hz)
– M201: 2,5A (230Vac/50Hz)
– M201M: 6,3A (125Vac/60Hz)