11
Maximum grid charging current
12
Maximum grid charging current
13
Low battery voltage transferred to
the grid
18
Alarm control
19
Auto return to default display screen
20
Backlight control
22
Beep when the primary energy
source is interrupted.
25
Fault code record
26
Bulk charging voltage
Maximum charging voltage for lithium
battery, when the battery voltage is
reached, it ends charging.
27
Floating charging voltage
Low battery voltage under charge (for
lithium battery)
www.intipv.com
The default value is the maximum one, with 5A as a base and 0A as the minimum one, it
can be set up or down. The maximum value cannot exceed Pout * 0,42 / Vdc.
The default value is the maximum one, with 5A as a base and 0A as the minimum one, it
can be set up or down. The maximum value cannot exceed Pout * 0,42 / Vdc.
The default value is the low voltage alarm point of the battery abled to be set between
10,5V y 12.5V (*2@24V, *4@48V). The increase of each click is 0,1V for 12V, *2@24V and
*4@48V.
Alarm on (default)
Return to default display screen
(default)
Backlight on (default)
Alarm on (default)
Record enabled
If selected "User-defined" as 94 in the program, the charging voltage can be set, the setting
range is between 13,0V and 15,5V for 12V (*2 @ 24V, *4 @ 48V)
If selected "User-defined" as 94 in the program, the maximum charging voltage can be set
between 13,0V and 15,5V for 12V (*2 @ 24V, *4 @ 48V)
If "User-defined" is selected as 94 in the program, the charging voltage can be set between
13,0V and 15,0V for 12V (*2 @ 24V, *4 @ 48V))
If "User-defined" is selected as 94 in the program, the charging voltage can be set between
12,0V and 14,0V for 12V (*2 @ 24V, *4 @ 48V)
MANUAL DE USUARIO INVERSOR TECA LITIO / USER MANUAL INVERSOR TECA LITIO
Alarm off
If selected it will return to the main screen (Input voltage
/ Output voltage) after no button is pressed for 1 minute.
If selected, the screen will stay on the latest one selected
by the user.
Backlight off
Alarm off
Record disabled
23