ASSEMBLY
ASSEMBLY OF THE PROTECTION SHIELD
WARNING: Always switch the tool off before you insert or remove the
rechargeable battery.
Slide the included protection shield (4) over the blade rail and fix it from
both sides at the housing using 1 screw on each side as shown.
INSTALLING AND REMOVING THE RECHARGEABLE BATTERY
WARNING: Always switch the tool off before you insert or remove the
rechargeable battery.
If you want to remove the rechargeable battery from the tool, press the interlock
of the battery and pull the it from the tool To insert the rechargeable battery in
the tool, first line up the base of the rechargeable battery with the guide on the
housing. Then push the rechargeable battery firmly into the tool until hear the
locking click into place. If the rechargeable battery is not locked into place, you
or other persons may be injured.
CHARGING BATTERIES WITH RAPID CHARGER
WARNING: Only use 20V Westinghouse rechargeable battery packs and Westinghouse 2A
Rapid Charger.
1.
Plug the charging device (8) into the mains socket.
2.
Make sure that the mains voltage cited on the charging station
complies with the voltage supplied by your socket. The green light on
the right side of the charging station will blink.
3.
Slide the rechargeable battery (6) into the charging station. It can only
be inserted in one position.
4.
The battery charging process now begins and is signaled by the
red indicator light on the charging station (9). The 4 green LEDs on
battery (6) light up in turn.
5.
Once the rechargeable battery has been fully charged, the green
indicator light on the charger will illuminate (9) and red LED turns off.
The charging process ends automatically.
6.
Charging takes approx. 1-1.2 hours. The battery heats up during the charging process. This is
normal and does not signal a fault. Do not let battery remain on charger for more than 5 hours.
Note: Occasionally, the permissible temperature range may be exceeded during the charging cycle.
In this case, the electronic charging control interrupts the charging cycle to avoid any damage to the
battery. The red control light will then glow continuously. If you should witness this, pull the battery
from the charging station and let it cool down for about 30 minutes. Then, restart the charging cycle
by sliding the battery back onto the charging station.