Technical Information / Données techniques / Datos técnicos
Recommended water
pressure
Recommended hot water
temperature
Max. hot water
temperature
Flow rate (per spray
mode)
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater.
* Vous devez connaître et respecter tous les codes de plomberie locaux applicables pour le réglage de la température du
chauffe-eau.
*Debe conocer y cumplir todos los códigos locales aplicables para ajustar la temperatura del calentador de agua
Installation Considerations
• For best results, Hansgrohe recommends that
this unit be installed by a licensed, professional
plumber.
• This unit requires iBox Universal Plus rough
01850181.
• The rough must be installed and the finished wall
surface must be complete and made watertight
before installation of this unit.
• This unit must be installed with Quattro Green
diverter rough 15936181 (included). Please
refer to the installation instructions included with
the rough. The trim kit for the Quattro Green is
sold separately.
• The Quattro Green insures that the flow rate of
the showerhead does not exceed 2.5 GPM. It
does not permit the use of two functions at once.
• There are no controls on the Raindance Rainfall.
The spray functions are controlled by the
Quattro Green diverter.
• Hansgrohe also recommends iBox Universal
plus 01850181 with a thermostatic mixing valve
6
Pression de service conseillée
Température recommandée
Température max. d'eau
chaude
Capacité nominale
Presión recomendada en
servicio
Temp. recomendada del
agua caliente
Temperatura del agua
caliente
Caudal máximo
trim and volume control valve 15977181 with
matching trim. Valves and trims are specified
and sold separately.
• To prevent scald injury, the maximum output
temperature of the shower valve should be no
higher than 120°F. In Massachusetts, the maxi-
mum output temperature of the shower valve can
be no higher than 112°F.
• This showerhead should not be used with a
continuous flow water heater.
• Please read over these instructions thoroughly
before beginning installation. Make sure that
you have all tools and supplies needed to com-
plete the installation.
• Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product
in a safe place. The receipt is required should it
be necessary to request warranty parts.
22 - 60 PSI
1.5 - 4 bar
120° - 140° F*
48° - 60° C
140° F*
60° C
2.5 GPM
9.4 liters/min