o
Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a
lead-acid battery. A lead-acid battery can produce a short-circuit current high enough to weld a ring
or the like to metal, causing a severe burn.
o
Be extra cautions to reduce risk of dropping a metal tool onto battery. It might spark or short-circuit
battery or other electrical part that may cause explosion.
o
NEVER smoke or allow a spark or fl ame in vicinity of battery or engine.
GUIDE TO LED INDICATIONS
•
Solid Green – Ultracapacitor ready to start vehicle.
•
Blinking Green – Ultracapacitor ready to start vehicle.
(May not have suffi cient charge to start vehicle.)
•
Blinking Yellow – Ultracapacitor charging.
•
Blinking Red – high temperature issue – Wait for product to cool down.
•
Blinking Red with Buzzer – Safety Issue, disconnect clamps immediately.
o
Reverse Polarity
o
Short Circuit
o
Over voltage (connected to battery >15 V)
SAFE OPERATION INSTRUCTIONS
1. Safe Cable/Clamp Storage
–
When not in use, ensure the clamps are stored in the slots near the handle to prevent short-circuit or
unnecessary dirt or damage.
2. Charging
If at any time an audible alarm sounds and/or the red light fl ashes, immediately disconnect the
clamps from the battery terminals to prevent damage or injury.
NOTES
•
All instructions assume vehicle is negative ground.
•
Charging and boosting shall be performed by an experienced operator who has read and fully
understood this instruction manual.
–
Charging – Fully charged 12 V battery standalone or in a vehicle.
–
Connect the Red positive (+) clamp to the positive (+) terminal of the 12 V battery.
–
Connect the black negative (-) clamp to the vehicle chassis ground connection.
–
If a chassis ground connection is not available the black negative (-), clamp may be connected to the
negative (-) battery terminal.
–
Press the power button.
–
Wait for LED indicators to change from blinking yellow to a solid or blinking green light.
–
Disconnect the black negative (-) clamp from the vehicle chassis.
–
Disconnect the red positive (+) clamp from the positive terminal taking extra care to ensure the
clamps do not come in contact.
–
Store the clamps per the safe storage instructions.
NU-UCB12A_1017.indd 7
WARNING
7