Weather Sensor Menu
SENSORS
CURRENT ADJUST
TEMPERATURE
RAIN STATUS
FREEZE OFF AT
DRYOUT DAYS
Current Adjust
The percentage that the weather sensor is going to adjust the
irrigation runtime. Possible values range between OFF and
+150, though realistically, values will display between ±35%.
For example, if the evapotranspiration (ET) historical data
calls for a hot season, but the week has in fact been cloudy, the
"Current Adjust" might show "-20%" to reflect the decreased
runtime. It can also display "OFF".
Temperature
Displays the current temperature at the sensor location.
Temperature unit (Celcius or Farenheit) can be changed in the
controller preferences settings (see the EVOLUTION
manual).
10
Rain Status
Displays the state of the rain sensor: "Dry" or "Wet".
Freeze Off
The temperature at which irrigation will be turned off due to
---
cold temperatures. Selections range from 35°-45°F in 2 degree
81
F
°
increments.
DRY
1. Press
39
F
°
2. Press
02
Dryout Days
After a rain, it is not always necessary to resume irrigation right
away. Setting a Dryout Days period, from zero to 14 days,
delays the automatic resumption of irrigation.
1. Press
2. Press
Water Adjust
Water Adjust allows the runtime of all stations in all schedules
to be adjusted by a maximum of ±35%. So, for example, if
the programmed runtime for station 1 is 10 minutes, setting
a Water Adjust of +35% would adjust that run time to 13
minutes, 30 seconds. This is useful for seasonal changes.
®
user
1. Press
2. Press
or
to raise or lower the temperature value.
to input the value.
or
to increase or decrease the number of
days to "dryout".
to input the value.
or
to increase or decrease the percentage
of irrigation runtime.
to input the value.