Safety
Installation
Start-up
Read all instructions carefully before installation.
This cooler must be connected to 120 Volt AC, 60 Hz (cycle)
power only. NOTE: Improper voltage will void the pump
and/or motor warranties and may cause serious personal
injury or property damage.
This cooler must be plugged into a GFCI protected
receptacle, which has been properly installed in accordance
with all local and national codes. If you are not sure that the
receptacle is GFCI protected, consult with a qualified
electrician.
This cooler is equipped with a power cord having an
equipment grounding conductor and grounding plug. Do not
attempt to defeat this safety device by removing the
grounding pin.
Use of an extension cord is not recommended.
Do not operate if plug or cord is damaged in any way. If the
unit is damaged or malfunctions, do not continue to operate it.
Always disconnect electrical power to unit before attempting
to work on or service your cooler.
Pump water tube has a restricting orifice to assure proper
water flow rate to the pad. Do not remove this restrictor!
P
HOENIX
'
G
S
UIDE
C
M
ARE
ANUAL
Operation
Maintenance
Trouble Shooting
M
I
ANUFACTURING,
NC.
Congratulations: You have purchased a product of superior performance and design,
which will give the best service when properly installed, operated and maintained.
This guide will provide you with information needed to mount, operate, inspect, maintain,
and troubleshoot your window evaporative air cooler.
The first section, Installation and Start-Up, gives details for installation. The second
section, Maintenance, contains operational and maintenance instructions, while
Troubleshooting includes information on commonly encountered problems.
INSTALLER: Please deliver this guide to owner.
WARNING -
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING.
Remove the plug from the electrical receptacle by pulling on
the plug and not the cord.
Do not operate this blower (fan) motor with any solid-state
speed control device.
Do not operate this unit with pad frame or air outlet grille
removed, this may cause the fan motor to overload and
damage the motor.
NOTE:
Do not locate unit near exhaust or vent pipes as odors or fumes
may be drawn into cooler.
Use of anode devices, chemical additives or treatments in this
cooler will void the warranty.
Your warranty does not cover shipping damage. Report all
shipping damage at once to dealer or carrier making the delivery.
For future reference, record the model and serial numbers, date
and place of purchase of your evaporative cooler here:
Model #
Serial #
Date of Purchase:
Place of Purchase:
1-999-2461 Date: 10/13

Publicidad

Tabla de contenido
loading

Resumen de contenidos para PMI WH2906

  • Página 1 WNER UIDE SE AND ANUAL WINDOW COOLER MODEL WH2906 & HE2913 For Customer Assistance CALL 1-800-325-6952 DO NOT RETURN TO PLACE OF PURCHASE! Congratulations: You have purchased a product of superior performance and design, which will give the best service when properly installed, operated and maintained.
  • Página 2 INTRODUCTION Mounting the Cooler Installation normally involves locating the unit in a suitable window This manual is your guide to proper installation procedures along with and using the included chain mounting kit or the construction of a information about reasonable care and maintenance that will ensure platform or stand to support the weight of the cooler.
  • Página 3: Cooler Operation

    Turn on water supply and check for leaks. Adjust float to maintain the water level at 2” to 2 ½”. GENERAL INSPECTION Install Bleed-off (Model WH2906) Initial Start-up or Annual Inspection To minimize mineral scale “build-up”, use the included bleed-off assembly.
  • Página 4: Maintenance Schedule

    MAINTENANCE SCHEDULE Cleaning Water Pump & Hose Regular maintenance and periodic inspection is the key to long and CAUTION: Disconnect all electrical power to the cooler successful service from your cooler. The cooler should receive major before attempting to install, open, or service your cooler. servicing at least once a year, more often if conditions require (dusty environment, constant use, poor water quality, etc.) For maximum CAUTION...
  • Página 5: Wiring Diagram

    Changing Cooler Pad (Model WH2906) Changing Cooler Pad (Model HE2913) CAUTION: Disconnect all electrical power to the cooler CAUTION: Disconnect all electrical power to the cooler before attempting to install, open, or service your cooler. before attempting to install, open, or service your cooler.
  • Página 6: Troubleshooting Guide

    TROUBLESHOOTING GUIDE: Should an obvious problem occur with your cooler consult the following table. If you cannot correct the problem, or if it persists, contact qualified service personnel. CORRECTIVE ACTION PROBLEM / SYMPTOM POSSIBLE CAUSE Float valve out of adjustment Water draining from unit Adjust float to 2 1/2“...
  • Página 7: A Del Propietaro

    Í ANUAL DE SO Y UIDADO ENFRIADOR EVAPORATIVO de VENTANA: Modelo WH2906 & HE2913 Para Asistencia al Cliente LLAMAR 1-800-325-6952 NO REGRESARLO A LUGAR DE COMPRA! Felicitaciones: Usted acaba de comprar un producto de superior rendimiento y diseño, que la dará...
  • Página 8: Introducción

    INTRODUCCIÓN Montando el enfriador Ester manual es una guía de procedimientos para una instalación La instalación normalmente envuelve el situar la unidad en una propia junto con información de un cuidado razonable y ventana apropiada y usando el juego de cadena incluido o la mantenimiento que le asegurará...
  • Página 9: Inspección General

    2” a 2 ½.. Lista de inspección de pre-comienzo o anual PRECAUCION: Desconecte toda la corriente eléctrica Instale el sangrado (Model WH2906) del enfriador antes de intentar instalar, abrir, o darle Para minimizar la “acumulación de sarro’, servicio a su enfriador.
  • Página 10: Lista De Mantenimiento

    LISTA DE MANTENIMIENTO Limpieza de la bomba y manguera PRECAUCION: Mantenimiento regular e inspecciones periódicas son la clave de un Desconecte toda la corriente eléctrica bueno y prolongado servicio de su enfriador. El enfriador debe recibir del enfriador antes de intentar instalar, abrir, o darle servicio completo a menos una vez por año y más seguido si las servicio a su enfriador.
  • Página 11: Diagrama De Alambrado

    Cambiando el filtro (Modelo WH2906) Cambiando el filtro (Modelo HE2913) PRECAUCION: PRECAUCION: Desconecte toda la corriente eléctrica Desconecte toda la corriente eléctrica del enfriador antes de intentar instalar, abrir, o darle del enfriador antes de intentar instalar, abrir, o darle servicio a su enfriador.
  • Página 12: Trazando Fallas

    TRAZANDO FALLAS : Si un problema obvio ocurre en su enfriador, consulte la siguiente tabla. Si no puede corregir el problema, contacte a un representante competente de servicio. ACCIÓN CORRECTIVA: PROBLEMA / SÍNTOMA: CAUSA PROBABLE: Ajuste el flotador 2 1/2“ de profundidad de agua Válvula de flotador fuera de ajuste Derrame de agua en la unidad Libere el flotador de la obstrucción...