NOTE: Not all appliance bulbs will fit your refrigerator. Be sure to
replace the bulb with an appliance bulb of the same size, shape,
and wattage (no greater than 40 watts).
Changing the Refrigerator Light Bulb
1. Unplug the refrigerator or disconnect power.
2. Slide the light shield toward the back of the compartment to
release it from the light assembly.
First try the solutions suggested here or visit our website and reference FAQs (Frequently Asked Questions)
The refrigerator will not operate
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Power cord unplugged? Plug into a grounded 3 prong
outlet.
Is outlet working? Plug in a lamp to see if the outlet is
working.
Household fuse blown or circuit breaker tripped? Replace
the fuse or reset the circuit breaker. If the problem continues,
call an electrician.
Are controls on? Make sure the refrigerator controls are on.
See "Using the Control(s)."
New installation? Allow 24 hours following installation for the
refrigerator to cool completely.
NOTE: Adjusting the temperature controls to coldest setting
will not cool either compartment more quickly.

Changing the Light Bulb

TROUBLESHOOTING

to possibly avoid the cost of a service call.
In the U.S.A., www.jennair.com

Refrigerator Operation

3. Replace burned-out bulb(s) with appliance bulb(s) no greater
than 40 watts.
4. Replace the light shield by inserting the tabs on the shield
into the liner holes on each side of light assembly. Slide the
shield toward the front until it locks into place.
NOTE: To avoid damaging the light shield, do not force the
shield beyond the locking point.
5. Plug in refrigerator or reconnect power.
Changing the Freezer Light Bulb
1. Unplug refrigerator or disconnect power.
2. Remove the burned-out bulb and replace it with an appliance
bulb no greater than 40 watts.
3. Plug in refrigerator or reconnect power.
In Canada, www.jennair.ca
The motor seems to run too much
Your new refrigerator may run longer than your old one due to its
high-efficiency compressor and fans. The unit may run even
longer if the room is warm, a large food load is added, doors are
opened often, or if the doors have been left open.
The refrigerator seems noisy
Refrigerator noise has been reduced over the years. Due to this
reduction, you may hear intermittent noises from your new
refrigerator that you did not notice from your old model. Below
are listed some normal sounds with explanations.
Buzzing - heard when the water valve opens to fill the ice
maker
Pulsating - fans/compressor adjusting to optimize
performance
Hissing/Rattling - flow of refrigerant, movement of water
lines, or from items placed on top of the refrigerator
Sizzling/Gurgling - water dripping on the heater during
defrost cycle
Popping - contraction/expansion of inside walls, especially
during initial cool-down
Water running - may be heard when ice melts during the
defrost cycle and water runs into the drain pan
Creaking/Cracking - occurs as ice is being ejected from the
ice maker mold.
The doors will not close completely
Door blocked open? Move food packages away from door.
Bin or shelf in the way? Push bin or shelf back in the correct
position.
11