Strike Installation; Functionality Test - Lloyd's LC-1298 Guía Rápida De Instalación

Cerradura inteligente
Ocultar thumbs Ver también para LC-1298:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12.
Rear panel installation
1. Open the battery cover, located in the upper part of the rear panel
2. Plug the connection cable to the corresponding interface of the rear panel, then store
the excess cable inside the hole of the door
3. Align and join the rear panel to the back of the door, taking the iron spindle as a reference
and fixing it with the connexion screws
4. Insert 4 AAA batteries in to the battery compartment and place the cover again
13.

Strike installation

Door frame
14.

Functionality test

1. Keep the door half-open while testing
2. Check correct operation of:
• Press down on the front handle, the dead-bolt and latch-bolt remain in place on lock status
• Unlock the device and press down on the front handle, the dead-bolt and the latch-bolt
retract in unlock status
• Lift the front handle, the dead-bolt is released to lock the door in any status
• Press the rear handle down, the dead-bolt and latch-bolt retract to any status
• Lift the rear handle, the dead-bolt is released to lock the door in any status
3. Safety Lock: When inner security lock is placed in the lock position, only the administrator
will be able to open, the other users will not be able
Strike box
Screws for
strike plate
Strike plate
23

Publicidad

Tabla de contenido
loading

Tabla de contenido