16
10.1.4
Combi-Steamer or Oven, Blend "0"
NOTE!
The actual capacity may vary from the given values provided. Capacity is dependent on the overall
water quality, flow rate, inlet water pressure and the continuity of the flow rate.
ppm
CaCO
3
71
89
107
125
143
161
178
196
214
232
250
267
285
303
321
339
356
374
392
410
428
445
463
481
499
517
534
> 534
10.2 Chlorine Reduction
The VIZION HRS water filter systems have been tested and certified by NSF International according
to NSF/ANSI 42 for reduction of chlorine.
The concentration of chlorine in water entering the system was reduced to a concentration less than
or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42.
While testing was performed under standard laboratory conditions, actual performance of the
system may vary.
VIZION HRS
Reduction (influent challenge concentration 2.0mg/l)
Grains
Blend setting
per US gallon
(GPG)
German carbonate
hardness (°dKH)
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
>30
Filter capacity VIZION HRS
100
US
gallons
(Liters)
0
3,098
(11,725)
0
2,478
(9,380)
0
2,065
(7,815)
0
1,770
(6,700)
0
1,548
(5,860)
0
1,376
(5,210)
0
1,239
(4,690)
0
1,125
(4,260)
1,032
0
(3,905)
0
952
(3,605)
885
0
(3,350)
0
826
(3,125)
774
0
(2,930)
0
728
(2,755)
688
0
(2,605)
0
651
(2,465)
620
0
(2,345)
0
589
(2,230)
563
0
(2,130)
0
538
(2,035)
515
0
(1,950)
0
495
(1,875)
476
0
(1,800)
0
458
(1,735)
443
0
(1,675)
0
427
(1,615)
412
0
(1,560)
0
375
(1,420)
100
%
200
US
gallons
(Liters)
5,466
(20,690)
4,373
(16,552)
3,644
(13,793)
3,124
(11,823)
2,733
(10,345)
2,429
(9,196)
2,186
(8,276)
1,988
(7,524)
1,822
(6,897)
1,682
(6,366)
1,562
(5,911)
1,458
(5,517)
1,367
(5,173)
1,286
(4,868)
1,215
(4,598)
1,151
(4,356)
1,093
(4,138)
1,041
(3,941)
994
(3,762)
951
(3,598)
911
(3,448)
875
(3,310)
841
(3,183)
810
(3,065)
781
(2,956)
754
(2,854)
729
(2,759)
663
(2,508)
200
> 50 %