1] PRODUCT PRESENTATION

Wiegand 26, 30 or 44 bit.
Direct connection or with the door controller
(INTBUSW).
PCB sealed in epoxy.
audible and visual feedback.
30cm pigtail wire connection.
Versions available: white or black.
Dimensions (L x W x D): 130 x 90 x 28mm.
Technology: 13.56Mhz.
Input voltage: 12V dc.
Consumption: 220mA.
-25°C to +70°C
CE Certification
IP53
Certification FCC CFR 47
WEEE
part 15 compliance
2] REMINDERS AND RECOMMENDATIONS
Important
To protect the device from
back-emf, do not forget to
install the varistor across the
lock terminals, in parallel.
Suggested power supplies
ARD12 & BS60 (in case the
reader is powered neither
by the controller nor by the
reader controller INTBUSW).
These
products
must
powered in 12Vdc and the
power
supply
should
3] MOUNTING KIT
Foam seal
SOLARMW(MB)
8
cdvigroup.com
Reader - Wiegand
certified
EN60950-1:2006/
A11:2009
standards
should be designed to be a
low power supply source.
Recommended cables
4 twisted pairs 0.6mm (AWG 24).
This product is supplied
with a varistor.
The
varistor
be
connected directly to the
locking
system
be
(electric
strikes,
3x30
TF screw
1
2
35
magnet, or lock) operated
and
by the device. If the device
functions with several locking
systems, each one must
be fitted with a varistor.
The varistor limits overload
produced by the strike coil,
known
as
back-emf. If you are using
a "Shear Lock", electromagnet
must
be
or other type of electric lock,
we recommend the use of
terminals
a dedicated power supply
electro-
for the lock.
S5 Plastic
Torx
®
anchor
2
1
90
self-effect
or
illumination,
the product.
3x8
bit
Torx
screw
®
1
EN
For optimal
do not fold
the cable
inside
Varistor
1