Kitchen Extractor fans
The kitchen extractors CK-25/40/40F/60F
have been manufactured in accordance
with the rigorous standards of produc-
tion and quality control laid down by the
international Quality Standard ISO 9001.
All components have been checked and
each of the finished products has been
tested at the end of the manufacturing
process.
On receipt of the fan we recommend
that you check the following:
1- That it is the correct model
2- That the details on the rating label
are those that you require: voltage, fre-
quency etc.
Installation
- The installation and wiring must be ca-
rried out in accordance with the electri-
cal standards in force in your country.
- The extractor should be installed at a
minimum height of 650 mm above the ho-
tplates or 750 mm from any burner rings.
- If the extractor operates in a room with
a boiler or any other type of appliance re-
quiring air for combustion, check that air
replacement inlets are sufficiently sized.
- The extractor outlet must not be con-
nected to a duct used to exhaust smoke
or fumes from any appliance that uses
gas or any other type of fuel.
- Children should be supervised to
ensure that they do not play with the
appliance.
- This appliance can be used by children
aged from 8 years and above and persons
with reduced physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given
supervision or instruction concerning use
of the appliance in a safe way and
understand the hazards involved. Chil-
dren shall not play with the appliance.
Cleaning and user maintenance shall not
be made by children without supervision.
Electrical wiring
- Before proceeding with the installation
and electrical wiring, make sure that the
mains supply is switched off.
- The extractors have been designed for
a single-phase supply, with voltage and
frequency as indicated on the rating plate.
- The extractors have been designed
with double electrical insulation (class
II), and therefore do not require an earth
connection.
- The extractor comes with the lead out
for connection to the mains. Except for
the CK-60F which has a two-speed mo-
tor, you can connect to the mains using
a normal plug correctly sized to match
the electrical load.
- The electrical installation must inclu-
de a double pole switch, with a contact
clearance of at least 3 mm, correctly
sized and in accordance with the elec-
trical standards.
Mounting
Installation can either be by wall moun-
ting (fig.1), or at the top of a kitchen hood
(fig.2). A bag containing the necessary
screws and plugs for either installation
is supplied with the unit, together with
a template.
Wall mounting
This is easily achieved with two simple
wall hooks and a fixing screw (fig.3).