2.8
ø 60 PIPING SYSTEM
A special kit allows to separate smoke
outlet and air intake pipes. The ø 80 intake
pipe may be installed to the right or left of
the ø 60 smoke pipe, indifferently. Both
pipes may be oriented in any direction.
Refer to fig. 10 for positioning of boiler con-
nections. Maximum total length, obtained
by adding together the lengths of intake
and flue pipes, is determined by the load
loss of individual accessories inserted and
must be no more than 12,5 mm H
102
TABLE 2/a
Accessories ø 60
90° elbow MF
Extension L. 1000
Outlet terminal
"T" connection
vers.) and 15,5 mm H
Refer to Table 2 for head loss of ø 80 intake
O ("25"
pipe accessories; refer to Table 2/a for
2
KEY
1
Separate pipes kit code 8089906
INLET PIPE ø 80
2a 90° MF elbow code 8077404
2b 90° elbow MF with take-off
points code 8077407
3a Extension L. 1000 code 8096000
3b Extension L. 500 code 8096001
4
Kit ghiere int.-est. cod. 8091500
5
Inlet terminal cod. 8089500
6
45° elbow code 8077406
head loss of ø 60 exhaust pipe accessories.
Total head loss
(mm H
O)
2
2.8. 1
"25" vers.
"30" vers.
1, 1
1,3
The complete range of accessories requi-
0,7
0,9
red for this type of installation is shown in
0,6
0,8
fig. 14.
1,4
1,6
WARNING: The smoke safety stat kit
O ("30" vers. ).
code 8089815 is required for protection
2
if there is a ø 60 exhaust pipe. Refer to
the wiring diagram in figg. 16-17.
OUTLET PIPE ø 60
7
90° elbow code 6295005
8a Extension L. 1000 code 6295000
8b Extension L. 500 code 6295001
9
Supporting bracket code 6295035
10 Condensation drainage plug code 6295020
11 Tee joint code 6295010
12 Locking collar code 6295025
13 Outlet terminal code 6295030
Accessories completing installation
Fig. 14