Full Programming Options
Full Menu Structure
Quickstart >
Tel. Numbers >
Alarm no.1
Alarm no.2
Alarm no.3
Alarm no.4
Tech.no.
Background no.
Call attempts
Settings
>
ID Code
Volume
System Config >
HW Monitoring >
Delays
>
COP delay
AS delay
Tech IP delay
Hangup delay
Answer delay
Redial del.
VAD timeout
Messages
>
Location
Reassurance
Guidance
Time/Date
>
Time
Date
Advanced
>
Passcode
Network ID
Next EN81 call
PBX Frequency
Language
Relay mode >
Relay override>
GMT Offset
Templates
Load Template
Save Template
Del. Template
Menu Sections explained...
Settings
ID Code
If using Memco GlobalNet to monitor the C100 enter the following:
Volume
Press the up and down arrows to adjust the volume, and press
confirm.
System Config
Sets how the system will operate. Select / deselect which modes of
operation are required in the system using the
explanation of each option:
System Config
>
[3 digit customer number][Unit ID code]
Multi-dial
EN81-28 Mode
Consec. dial
Alt. dial tone
Verbal c/down
Passcode?
EOA pictogram
Alarm tone
Hotline
Auto Location
Avoid Silence
to
key. See below for a full
Sets the unit to call each of the
programmed alarm numbers one after
the other.
Prevents the unit from accepting
incoming calls when not in an alarm
state and requires a passcode to enter
remote programming.
Changes the dialling sequence; all
call attempts to the first number are
completed before unit attempts to call
the second number and so on.
Allows system to work with an
intermittent dial tone.
Units gives a verbal countdown until
the emergency call is placed.
Require a passcode to be entered
before accessing the 'System Config'
menu.
Sets the system to keep the alarm
pictogram lit whilst the unit is in an
alarm state.
Sets the unit to emit a tone from the
internal speaker when the alarm push
is pressed.
Use if setting as a hotline. A hotline
is where the C100 will automatically
connect to another extension within
the building telephone exchange.
When an operator answers an alarm
call, the C100 will automatically play
the location message.
NOTE: when programming in the alarm
numbers 'UNGUIDED' protocol must
be selected (see section on Alarm
Numbers for more detail).
During an alarm call the C100 will not
mute its speaker, unless the operator
presses the '2' key on their handset.