Faults and remedies

6
Faults and remedies
If a problem occurs with the EFOY GO!, the red LED on the battery indicator flashes
and the four green LEDs display an error code. The LEDs display the error code for
one minute and then go out. To display the error code again for 30 seconds, start-up
the EFOY GO! and press the ON/OFF button on the right (grey) for longer than 3
seconds.
The EFOY GO! can be restarted by pressing the Power ON/OFF button on the left
(green) for longer than 3 seconds.
Consult the following list to determine what your error code means and what needs
to be done:
LED
No.
display
0
1
2
Error codes
Problem
Description
Battery flat
The battery of your
EFOY GO! is flat.
Overheating
The device has
of the
switched off to protect
inverter
the inverter from
overheating
Overheating
The device has
of the
switched off to protect
internal
the charger from
charger
overheating
Solution
Charge the EFOY
GO! up. Charging
options are
described in chapter
4.2 "Charging the
EFOY GO!" on
page 30.
Wait until the
inverter has cooled
down.
Switch the EFOY GO!
back on.
Wait until the
internal charger has
cooled down. The
EFOY GO! switches
itself back on
automatically.