Descargar Imprimir esta página

Sanus LLL1 Manual Del Usuario página 12

Publicidad

2
B
2B.1
Verify Your Wall
Min. 3 1/2 in. (89 mm)
Min. 1 1/2 in. (38 mm)
Max.
16 in.
5/8 in.
(406 mm)
(16 mm)
CAUTION:
Avoid potential personal injuries
and property damage!
● Drywall covering the wall must not exceed
5/8 in. (16 mm)
● Minimum wood stud size: nominal 2 x 4 in.
(51 x 102 mm) actual 11/2 x 3 1/2 in. (38 x 89 mm)
● Minimum horizontal space between fasteners:
16 in. (406 mm)
● Stud centers must be verified – not all walls
have conventional 16 in. (406 mm) stud spacing
12
WOOD STUD
INSTALLATION
2B.2
1
Min.
Locate the center of BOTH
studs using a stud finder,
an awl or small nail.
apart – OR – you cannot center wall plate
2B on PAGE 12, for drywall installation.
[ TVs up to 135 lbs. (61.2 kg)]
Attach the Wall Plate
IMPORTANT:
If you DO NOT have two studs that are 16 inches (406 mm)
2
05
Position wall plate
over your
05
studs and mark the hole positions.
on your studs, follow STEP
05

Publicidad

loading