Troubleshooting

Problem
Camera video image
not seen
Flashing battery
warning appears
Count accuracy
unreliable (CountPlus)
Low battery warning
appears on screen
(CountPlus)
Low battery buzzer
sounds or both battery
LEDs turn red
The "+" symbol
appears after the
on-screen distance
measurement
(CountPlus)
SOS blinking on Power
Key LED
Contact Us
• Visit www.seesnake.com for updates on products, documentation, and videos.
• Visit www.RIDGID.com or www.RIDGID.eu to find your local Ridge Tool contact
point.
• Contact Ridge Tool Technical Service Department by email or phone:
• Email: rtctechservices@emerson.com
• Phone: +1-800-519-3456 in the U.S.A. and Canada, or +32 (0) 16 380 280 in
Europe.
SeeSnake CS10 Quick Start Guide
Probable Fault
No power to
SeeSnake
Connections faulty
18 V Li-Ion batteries
low
18 V Li-Ion batteries
low
CountPlus settings
incorrect for Reel or
cable being used
Counting from the
wrong zero-point
CountPlus battery
dead or near-dead
18 V Li-Ion batteries
low
Physical cable
measurement
has exceeded the
cable parameter in
settings
No video signal
Solution
Check power is correctly plugged in.
Check alignment and pins of
connection from CS10 to the
SeeSnake Reel.
Recharge batteries. Switch to AC
power.
Recharge batteries. Switch to AC
power.
Verify the settings are correct for
the SeeSnake cable length, cable
diameter, and SeeSnake Reel being
used.
Confirm measurement from the
intended zero-point. Reset zero-point
using the Zero Key.
Replace 3 V battery in the CountPlus
(CR2450).
Recharge batteries. Switch to AC
power.
Verify the actual length of installed
cable and reset the SeeSnake Reel
and cable settings in accordance with
the CountPlus Operator's Manual.
Reseat SeeSnake system cable
connection.
English – 9