Descargar Imprimir esta página

Dri-Eaz DefendAir HEPA 500 Manual De Instrucciones página 11

Ocultar thumbs Ver también para DefendAir HEPA 500:

Publicidad

Idiomas disponibles

Idiomas disponibles

Dri-Eaz
The 031400 is a portable cooling, heating and dehumidification system. The unit may be
READ AND SAVE THESE INSTRUCTIONS
TAWARNiNG1
Read and understand manual before operating.
ELECTRIC SHOCK HAZARD
WARNING! Unit must be grounded.
• Use indoors only
• Keep out of water.
• Keep electrical components dry if they get wet, allow
them to dry before using the EB1400.
• Insert three-prong plug on power cord into a matching
electrically grounded outlet Never cut off third prong.
FIRE HAZARD
• Keep air intakes clear of obstructions and dirt Reduced
airflow can cause motor to overheat Keep away from
draperies or other material that could block air intakes.
See maintenance instructions.
• Keep air filter clean. Keep filter clear of clogging, oil,
grease or other contaminants that can be drawn into the
EB1400.
SAFETY INSTRUCTIONS
WARNING! Unplug unit before opening housing for
cleaning or servicing.
• Turn off unit and unplug before lifting or moving.
• Handle the unit carefully. Always operate the unit on a
stable, level surface. Do not drop, throw, or place where it
could fall. Rough treatment can damage the unit, and may
create a hazardous condition or void the warranty.
• Inspect the power cord before use If cord is damaged, do
not use Replace with a cord of the same type and
amperage rating. Protect cord from damage by turning off
unit before unplugging. Always grasp the plug (not pulling
on the cord) to unplug.
• The unit is designed to operate on 115V/60 Hz. Make sure
that the electrical outlet is grounded.
141
kinderkamack Rist Park Ridge, NJ 07686 Tel: 201-782-1782 Fax. 201-782-1783 Web: wwwamgaircom Email. info©amgaircom
F388 Owner's Manual
®
EnviroBoss
Air Marketing Group LLC
141 Kinderkamack Rd, Park Ridge NJ 07656
Phone 201-782-1782 Fax 201-782-1783 www.amgaircom
ducted for directing cooled or heated air into specific spaces.
rrn
••
•• ?tc.
Air Marketing Group
TM
1400(115V)
• Secure during transport to prevent sliding and possible
injury to vehicle occupants.
• Keep children away from unit Be sure unit is inaccessible
to children when unattended
• Do not attempt to disassemble or repair the unit For
Authorized Service Centers, go to
Lim w.dri-eaz.comMowtobuy or call Dri-Eaz Service at
800-932-3030
INTRODUCTION
The E131400 is a versatile unit providing dehumidification, 1-ton
cooling with 470 CFM across the evaporator and 750 CFM
across the condenser, plus focused heating and ventilation.
4
1
,
The unit can be ducted for spot cooling and directing
conditioned air or heat into specific spaces while filtering room
air and pumping out condensate
FEATURES:
• Ducts to and from unit for heating and cooling. Note: Duct
adapters for condenser inlet and outlet and evaporator
outlet No duct adapter for evaporator inlet
• Refrigeration system that dehumidifies while it heats or
cools
• Uniform B'' ducting size for all outlets
• Digital temperature control
• Durable rotomolded duct rings and housing
• Wheel casters and handle for ease of transport
LLC

Publicidad

loading