Select Default Configuration - "Def; Select Power-Up Test Setting - "Put - Macurco CD-6B Instrucciones Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Macurco CD-6B Manual (Rev-1.0) Eng
4.8.1 Select Default Configuration – "dEF"
Available options are "YES", "nO".
NOTE: This menu cannot be changed when the CD-6B is in calibration due or calibration overdue. (Refer to Section
4.8.16 Calibration Period – "CAL" for information on calibration due and calibration overdue.)
To select the Default Configuration (this will reset the device to its default settings), in normal mode:
1. Push the Next button to get to "Con" or the Configuration menu.
2. Push the Enter button to enter the Con menu.
3. The first selection is the "dEF" or Default setting. Push Enter.
4. If it is already in Default configuration, "YES" will be displayed and there will be no available action. If it is
not already in Default configuration, "nO" will be displayed.
5. Push Next to change it to "YES" (display will begin flashing).
6. Push Enter to confirm resetting the device to its default settings (display will stop flashing).
7. Push Enter once more to return to the configuration menu.
8. Push Next until "End" is displayed.
9. Push Enter to return to normal operation.
4.8.2 Select Power-Up Test Setting – "PUt"
Available options are "OFF", "On".
To select the Power Up Test Configuration, in normal mode:
1. Push the Next button to get to "Con" or the Configuration menu.
2. Push the Enter button to enter the Con menu.
REV – 1.0
Figure 4-1 Board View
[34-2900-0510-2 ]
16 |
P a g e

Publicidad

Tabla de contenido
loading

Tabla de contenido