If, for any reason, it is necessary to retrieve the operating time and the automatic closing factory-programmed, you must
follow the process indicated below:
1 .- Disconnect the power supply 220V
2 .- Set the selector switches in the following location:
I1 = OFF
I2 = ON
I3 = OFF
I4 = ON
3 .- Remove any cable connected to terminal 9.
4 .- Power up the control unit to 220V
A buzz indicates that the process is complete. Restore the wires connected to terminal 9 and replace the switches in the
same position they were before starting the process.
STORING TRANSMITTER CODE
To store the codes of the transmitters, the control unit must be in a stable condition and the door closed.
Manual
a)
Storing
To store a code, press the program button PROG/RES until the buzzer is on. The red Led lights on, and when the button is
released, the LED keeps lit indicating that the device is ready to store the code of the transmitter. From this moment on, any
code will be stored. To do this press the transmitter function with which we want to enable the automatism. The red LED,
accompanied by the buzz begins to flash confirming the execution of the storage. After 10 seconds of the last reception of a
code, the unit will automatically exit the storage mode by turning off the red LED and emitting two short beeps.
Storing
b)
via radio transmitter
To use this system, you must have previously stored at least one code with the system a).
Press the special function of a previously stored transmitter because the device enters the code sequence, the red LED lights
and activate the buzzer. From this moment, any code received with the same function, with which you have stored the trans-
mitter used with the special function, will be stored.
To do this, press the transmitter with the same previously function stored by the transmitter used for this system. To store any
other function (button) use the system a). We will get confirmation of storage by means of light flashing red LED and a short
beep. The control panel will automatically exit the storage mode after 10 seconds of the last reception of a code, turning off
the red LED and emitting two short beeps. You can force the exit before time by pressing the special function of a transmitter
memory.
CANCELLATION OF ALL CODES
The reset of memory causes the cancellation of all codes. Press SET/RES for 4 seconds. It produces a blasting of red flashing
lights and a beep indicates the cancellation of all previously stored codes. The unit will remain in the learning sequence of
codes waiting to memorize new ones.
FULL MEMORY INDICATION
If you have run out of memory and, after storing 31 different codes, you try to store new codes, the LED will flash red and you
will hear a series of beeps for 10 seconds when trying to introduce a new code.