3. Position the tool at the point where the next fastener is to be driven and repeat the steps described. In
doing so, observe the information shown in the display. → page 5
Nail stand-off should be checked immediately after driving the first fasteners and subsequently at
regular intervals so that the driving power of the tool can be set to the right value in order to ensure
that fasteners are driven correctly.
5.2.2

Checking the nail stand-off

1. Use the test gauge to check the nail stand-off.
Result 1 / 3
Nail stand-off is within the required range.
The tool power setting is incorrect.
complete.
Result 2 / 3
Nail stand-off is too high.
▶ Increase the power setting by turning the power
regulation wheel to the next higher setting.
Result 3 / 3
Nail stand-off is too low.
▶ Reduce the power setting by turning the power
regulation wheel to the next lower setting.
2. Drive another fastener.
3. Repeat the previously described steps until the correct nail stand-off is achieved.
5.2.3
Adjusting the power setting
▶ Turn the power regulation wheel to set the desired
nail driving power.
➥ The current power setting is indicated.
5.2.4
Removing cartridges from the tool
1. Press the cartridge strips forward, as far as possible, in the direction of advance.
2. Pull the cartridge strips out of the tool at the cartridge strip exit aperture.
5.2.5
Removing fasteners from the tool
The fasteners can normally remain in the tool. It is not necessary to remove them, for example, when
you are finished working with the tool.