BIOLOGICAL RECYCLING SYSTEM FLOW CHART
The Sump Pump (1) draws water from the Sump Pit (2) and brings it to the Inlet (3) of the Biological Recycling System.
The Inlet Flow Control Valve (4) can be used to control the flow of water into the unit. The Biological Recycling Tank
(5) is made up of several sections that are separated by weirs. The wastewater enters the top of the First Chamber (6)
and moves down through the Biological Media (7). The media packs provide a surface for the microbes to live on. As
water passes through the Biological Media (7), the microbes feed off of the organic compounds in the water, producing
by-products of carbon dioxide and water.
From the First Chamber (6), the wastewater moves under the weir, into the Second Chamber (8), rising up through
the Biological Media (7) and over the weir into the Third Chamber (9). The wastewater then flows down through the
Biological Media (7) for a final cleansing before moving into the Water Level Control Tank (10). This very small section
has a weir positioned to control the level of water in the Biological Recycling Tank (5). The water moves over this final
weir and into the Product Tank (11).
Microbes also need air to live; an Aeration Pump (12) pumps water from the Product Tank (11) to two venturi Air
Injectors (13) that pull air into the water. From there the air bubbles move up through the Biological Media (7). Without
the air in the Biological Recycling System, the microbes will not be able to live.
Water is also pulled from the Product Tank (11) by the Transfer Pump (14) and moved into the Manifold (15) and the
Pressure Tank (16). This tank holds water at 30-50 PSI (2.0-3.4 BAR) until needed. When water is needed for washing,
water is sent from the Manifold (15) to the Water Outlets (17) and then to a pressure washer or garden hose. If the
Product Tank (11) water level is low, water is added through the Fresh Water Makeup (18) to the Product Tank (11).
If the Biological Recycling Tank (5) water level is too high, treated water is sent to the Rain Water Overflow (19) and
disposed of.