LD8ART Commercial Recessed LED Retrofit
For Incandescent Housingse:
1.
Remove existing reflector/trim and lamp (Figure 19.).
2.
Adjust socket bracket to highest position.
3.
Locate junction box, remove cover and disconnect
supply wires (120 or 277). Disconnect connections to
insulation detector if any (Figure 20.).
4.
Remove one 7/8" diameter (1/2" trade size conduit)
knockout from junction box, on top if possible.
5.
Place retrofit driver assembly through ceiling/housing
opening (Figure 21.).
6.
Lay retrofit driver assembly away from ceiling/housing
opening with driver side up (Figure 22.).
7 .
Leave flexible conduits from retrofit driver assembly
hanging down out of ceiling/housing opening.
8.
Feed supply wires from retrofit driver assembly through
knock-out that was removed in junction box and insert
snap-in connector into junction box (Figure 23.).
9.
Reconnect supply wires in junction box to leads from
retrofit driver assembly: black wire to line,white wire to
neutral, green wire to ground (see Wiring Diagrams).
10. Replace ballast/junction box cover to completely close
junction box.
Retrofit Ring Assembly Installation
1.
Slide Adapter Band Ring (optional) over Retrofit Ring
Assembly while holding mounting springs vertical
(Figure 25.).
2.
Hold 2 mounting springs vertical on same side of
Retrofit Ring Assembly then insert into ceiling/housing
opening (Figure 26.).
3.
Use ceiling/housing opening to keep mounting springs
from Step 2 vertical and push other 2 mounting springs
vertical then insert into ceiling (Figure 27 .).
4.
Align torsion spring receivers with housing stilts (if
present) and ensure that mounting springs do not
contact any part of housing so mounting feet or
Adapter Band Ring (if present) rest flush on ceiling.
Retrofit Ring Assembly may need to be rotated to avoid
interference (Figure 28.).
5.
Retrofit ring can be adapted to various ceiling
thicknesses and plaster frame/housing heights by using
different slot locations for mounting springs. LD8ART
ships with springs in upper position for a combined
ceiling and housing thickness greater than 1" and no
more than 2" . For ceiling/housing thicknesses between
0.5" and 1" mounting springs should be moved to
lower position (Figure 29.).
Figure 19.
Figure 21.
Figure 23.
Figure 25.
Figure 27.
Upper Position
Lower Position
Figure 29.
LD8ART Commercial Recessed LED Retrofit
706240INS
ADP140604
www.eaton.com
Figure 20.
Figure 22.
Figure 24.
Figure 26.
Figure 28.
4