PROGRAMMING
Start the programming procedure on the control unit and select
i.Adi
the menu
Si
1. Select the item
and press OK: the display shows
NOTE: to display the firmware version of your device, press the
OK key
h
i
2. Using the keys
and
select the output (
whose operation logic you want to program and press OK
3. Using the keys h and i select the parameter you want to
program:
AUX
Auxiliary Channel: the relay output is controlled by a
transmitter stored on channel 4 of the receiver
embedded in the control unit. The relay output can be
programmed with different operation logics
LAM
Flashing light. According to the programmed logic the
relay output is activated in an intermittent manner
during the gate opening / closing / pause stages
i.Adi
LUX
rEL1
rEL2
or
)
4. After programming the parameters, select the item
no
Si
rEL2
SAvE
- 11 -
LUCE
Courtesy light. According to the programmed logic
the relay is activated when the control unit receives a
START command
SEM
Semaphore. The relay output is opened or closed
depending on the settings of the various stages of the
operation cycle (gate stopped and closed, gate
opening, gate closing, gate stopped, gate paused)
LSW
Limit switch signal. The relay output is used to signal
the achievement of the limit switches of the leaves.
FrEn
Electric brake. The relay output controls the electric
brake of the motor, by opening or closing when the
motor is operated.
save the settings and the item
menu
Fv I.0
rEL1
ESC
SAVE
ESC
to exit the programming
LUCE
LSW
FrEn
to