CONTROL UNIT
0 - AUTOMATIC MODE
closed
opened
closing
opening
locked by STOP while closing
locked by STOP while opening
1 - 4-STEP
closed
opened
closing
opening
locked by STOP while closing
locked by STOP while opening
2 - SUPER AUTOMATIC
closed
opened
closing
opening
locked by STOP while closing
locked by STOP while opening close
3 - SEMIAUTOMATIC with STOP
closed
opened
closing
opening
locked by STOP while closing
locked by STOP while opening
4 - STEP-BY-STEP
closed
opened
closing
opening
locked by STOP while closing
locked by STOP while opening
Legend:
lock
1
: locks and inhibits signals until a START command
lock
: locks until a START command to close
2
lock
: locks until a START command to close ignoring pause time
3
lock
: locks as long as the photocell is covered, ignoring pause time
4
lock
: if the START command is given within the fi rst 3 seconds of the opening pause, will lock until a new START command is given to close
5
lock
: in spite of a START, the gate is locked as long as the photocell is covered, then it will close
6
lock
: locks as long at the photocell is covered; when the photocell is uncovered will complete the movement
7
lock
: locks until a START command to reopen
8
close
: closes ignoring the pause time - NOTE: If this occurs after an obstacle is detected during closing, will LOCK until
1
a new START is given to reclose slowly
reopen
: reopens slowly
1
reopen
: reopens - NOTE: If this occurs after an obstacle is detected during opening, will LOCK until a new START is given to reclose slowly
2
reverse and lock: reverses the movement for 2 seconds and locks - a START is necessary to reclose slowly
START
STOP
closing safety opening safety edge
1
open
lock
-
-
lock
3
lock
4
reopen
2
lock
2
reopen
2
-
lock
-
close
-
-
close
-
-
START
STOP
closing safety opening safety edge
open
lock
1
-
lock
5
lock
3
lock
4
2
2
reopen
lock
reopen
2
-
lock
-
close
-
-
close
-
-
START
STOP
closing safety opening safety edge
1
open
lock
-
close
1
lock
3
lock
4
reopen
lock
2
reopen
2
reclose
lock
-
close
-
-
-
-
START
STOP
closing safety opening safety edge
1
open
lock
-
1
6
close
lock
lock
reopen
lock
2
reopen
lock
2
lock
2
-
close
-
-
close
-
-
START
STOP
closing safety opening safety edge
1
open
lock
-
close
lock
1
lock
6
8
2
lock
lock
reopen
2
2
lock
lock
-
close
-
-
close
-
-
- 22 -
RSK24-2000/2500
pulse/signal
opening photocell
-
-
2
-
reverse and lock
-
-
pulse/signal
opening photocell
-
-
2
-
reverse and lock
-
-
pulse/signal
opening photocell
-
-
2
-
reverse and lock
-
-
pulse/signal
opening photocell
-
-
2
-
reverse and lock
-
-
pulse/signal
opening photocell
-
-
2
-
reverse and lock
-
-
obstacle detection
-
-
lock
4
-
lock
7
reopen
1
7
lock
reverse and lock
-
-
-
-
obstacle detection
-
-
lock
4
-
7
1
lock
reopen
7
lock
reverse and lock
-
-
-
-
obstacle detection
-
-
lock
4
-
lock
7
reopen
1
7
lock
reverse and lock
-
-
-
-
obstacle detection
-
-
6
lock
-
lock
7
reopen
1
lock
7
reverse and lock
-
-
-
-
obstacle detection
-
-
lock
6
-
7
1
lock
reopen
7
lock
reverse and lock
-
-
-
-