INSTALLATION
Separate the front housing of thermostat from wall module:
1.
Unscrew both closing screws (bottom of thermostat) until they will not turn any further
2.
Release front housing by gripping lower half of outer frame and pulling outwards then
upwards
3.
Place front housing somewhere safe
4.
Run all wires to the wall box. Check to ensure that you have included the following:
Power (Live and Neutral)
Heater (Live and Neutral or Switch Live only)
Floor sensor
Fil pilote (if necessary)
5.
Pull wires through wall box and complete terminal wiring
IMPORTANT: Ensure that multi stranded wires are fully inserted into the terminals and secured
tightly. Any loose strands should be trimmed as they could cause a short-circuit. If connecting
more than two heaters, an electrical junction box will be required.
NOTE: Always ensure that the sensor cable is installed in a separate conduit to the power cables
supplying the thermostat and heating system.

ELECTRICAL SPECIFICATION:

Model: BU-SC-NG-01
Code: 100232083
Supply voltage: 230V +/-10% at 50Hz
Thermostat is not designed for use with intermittent power supply
Maximum Switch Load: 16A resistive
Insulation Class: II
IP33
Operating frequency: 2401-2483MHz;
Maximum radio-frequency power transmitted: 18dBm
Standards: EN60730-1 & EN60730-2-9
NOTE: This product is in compliance with the essential requirements and other relevant
provisions of the RED Directive 2014/53/EU. The Declaration of Conformity may be consulted by
visiting: butech.net/mi-suelo-radiante/declaracion-de-conformidad.