Pre-Operation Checklist

• Check for adequate water and chemical cleaner supply (use only mild cleaners).
• Make sure the battery has sufficient charge for normal operation.
• Check spray nozzles and make sure orifice is not blocked or worn to excess.
• Check pressure hose for wear or kinks.
• Check all connections, fittings, screws and fasteners.

Charging the Battery

1. The unit is supplied with a 12V sealed lead acid battery, which will provide up to 1 hour of
continuous use or approximately 4-6 hours of intermittent use when fully charged.
2. It will take approximately 4 hours to charge a fully discharged battery.
3. Make sure the power switch is in the "Off" position when charging.
4. An orange/red light means the battery is charging, a bright green light means the battery
is fully charged.
5. The unit can be left plugged in indefinitely - once the battery is fully charged, the battery
charger will switch to a "maintain charge" mode.

Changing the Battery

1. The battery can be quickly removed from the unit, allowing the insertion of a fresh battery.
Spare batteries and chargers are available – contact your local distributor or SpeedClean.
2. To replace the battery:
a. Turn power switch off.
b. Remove the battery door by pulling up.
c. Carefully remove the battery. Disconnect the battery terminal connectors from the
battery.
d. Connect the battery connection wires to the fresh battery (Caution - black battery
connection wire to the negative (black) battery terminal and red wire to positive (red)
battery terminal.
e. Replace the battery in the battery compartment and replace the battery cover.

Normal Coil Cleaning Operation

1. Fill the water and chemical tanks. Before priming the pump, make sure chemical valve is
fully closed and remove any nozzle from the spray gun.
2. Flip the power switch to the ON position.
3. Squeeze the spray gun trigger to prime the pump.
NOTE: If you are having trouble priming the pump, make sure the water tank is completely
full as well as having the chemical tank full, whether it's with chemicals or water. Place the
unit on a table or support, hold the spray gun below the level of the pump and squeeze
the trigger until a steady flow of water appears.
4. Fully open the chemical valve (counter-clockwise). Squeeze the spray gun trigger
repeatedly until chemical is primed.
5. Adjust chemical valve to desired dilution ratio (see chart on next page).
6. Attach nozzle to spray gun.
7. Apply water/chemical solution evenly to coils.
8. Close chemical valve finger tight (clockwise). DO NOT overtighten.*
9. If possible, let foaming coil cleaner solution sit for recommended dwell time (according to
chemical instructions) to penetrate into coils.
10. Rinse coils with clean water.
*NOTE: There may be a ten second delay for the chemical to be removed from the hose.
11. Flip Power Switch to OFF. Always relieve the pressure by pointing the spray gun in a safe
direction and squeezing the spray gun trigger.